Appendix
A.1 Process data and data sets
Data set
Index
Index
Subindex
(dec)
(hex)
supported
92
5C
Yes
94
5E
Yes
131
83
Yes
A.1.1.2
IO-Link communication parameters
Parameter Page 1 - IO-Link communication parameters
Table A- 2
Parameter Page 1
Address
Parameter name
0x00
Master Command
0x01
Master Cycle Time
0x02
Min. Cycle Time
0x03
M-Sequence Capability
0x04
IO-Link Revision ID
0x05
Process data IN
0x06
Process data OUT
0x07
Vendor ID 1
0x08
Vendor ID 2
0x09
Device ID 1
0x0A
Device ID 2
0x0B
Device ID 3
0x0C
Function ID 1
0x0D
Function ID 2
0x0E
Reserved
0x0F
System Command
576
Name
Diagnostics - data set 92
Diagnostics - data set 94
Parameters - data set 131
Access
w
r / w
r
r
r / w
r
r
r
r
r / w
r / w
r / w
r
r
r
w
Access Value
r
—
r
—
r / w
—
Description
—
—
FW 1.4.0 or FW 2.0.0 in compatibility mode: 0x6e
FW 2.0.0: 0x32
0x11
0x11
FW 1.4.0 or FW 2.0.0 in compatibility mode: 0x50
FW 2.0.0: 0x10
0x00
0x00
0x2a
0x0c
0x03
FW 1.4.0 or FW 2.0.0 in compatibility mode: 0x01
FW 2.0.0: 0x02
0x00
0x00
—
—
SIRIUS ACT 3SU1 pushbuttons and signaling devices
System Manual, 08/2018, A5E03457306020A/RS-AK/010
Length
(bytes)
20
22
20