Siemens SIRIUS ACT 3SU1 System Manual page 32

Industrial controls, command and signaling devices pushbuttons and signaling devices
Table of Contents

Advertisement

Overview
4.1 Overview of the device range
SIRIUS ACT pushbuttons and indicator lights
3SU10 actuating and
signaling elements
3SU11 complete units
3SU12 compact units
Safety
EMERGENCY STOP
mushroom pushbuttons for
shutdown of systems in an
emergency situation The
devices can be used up to
SIL CL 3 according to
IEC 62061 and PL e Cat. 4
according to ISO 13849-1.
Options
Link to the configurator for customized enclosures:
Configurator (http://www.siemens.com/sirius-act/configurator)
Do-it-yourself labeling using Label Designer.
Label Designer (http://www.siemens.com/sirius-label-designer)
(labels for self-inscription)
Holder included in the scope of supply
1)
IPX9 - Protection against high pressure and high jet-water temperatures
2)
● a) IPX9 according to EN 60529
The IPX9 test as defined by EN 60529 is carried out under standardized laboratory
conditions and certifies resistance of equipment to water penetration during cleaning with
high-pressure water.
According to the standard, the IPX9 test must be conducted with the following
parameters:
– Water temperature approximately 80° C
– Pressure approximately 80 bar
– Spray angles 0°, 30°, 60°, 90°, spraying time approximately 30 seconds
– Distance between spray nozzle and equipment approximately 125 mm
● b) High-pressure cleaners in practice
– Laboratory tests carried out in accordance with a standard can generally only
– In order to preserve the service life of the devices, therefore, it is recommended that a
Grained finish in combination with SIRIUS ACT actuators (3SU10, 3SU12)
You can use the SIRIUS ACT actuator in the front panel with a standard grained (hammered
enamel) finish. In this way, the SIRIUS ACT actuators comply with IP66 and IP67 protection.
32
3SU14 modules
without holder
3SU15 modules with
1)
holder
1)
Contact module with
installation monitoring
approximate a complex reality.
significantly larger distance than that specified in the standard for one-time loading is
maintained between the spray nozzle and the equipment.
3SU18 enclosures
3SU18..-3 two-hand
operation consoles
EMERGENCY STOP
EMERGENCY STOP
function with latching
function with latching
according to
according to ISO 13850
ISO 13850
SIRIUS ACT 3SU1 pushbuttons and signaling devices
System Manual, 08/2018, A5E03457306020A/RS-AK/010