3SU18 enclosures
10.1 Enclosures for actuating and signaling elements
10.1.3.2

Front plate mounting for enclosures

Front plate mounting for enclosures
The front plate mounting method for enclosures is described below. With enclosure
mounting, only 1-pole modules can be mounted. Stacking of modules is not possible with
enclosure mounting.
An adapter is available for the enclosure with 1 command point (article number:
3SU1900-0JF10-0AA0) to allow the installation of 2-pole contact modules. You will find
additional information in the Chapter "Accessories for the enclosure (Page 418)".
Requirement
The enclosure cover has been removed.
You need at least the following elements in order to construct a command point:
● An actuating or signaling element (3SU1) in front of the enclosure cover.
● A holder (3SU15) behind the enclosure cover.
● Contact modules and / or an LED module (3SU14) behind the enclosure cover.