12.3

Electronic modules for IO-Link

12.3.1

Electronic module for IO-Link

The electronic modules for IO-Link can be installed in 3SU1 enclosures or mounted on a
front plate.
The modules are controlled by IO-Link communication. The rated supply voltage of the
module is 24 V.
Variants
● Front variant 6DI/2DO
For front plate mounting. The 8 digital inputs and outputs can be parameterized
individually as required. The default setting is 6 digital inputs and 2 digital outputs. The
inputs and outputs can only be parameterized by IO-Link communication.
● Basic variant 6DI/2DO
For use in a 3SU1 enclosure. The 8 digital inputs and outputs can be parameterized
individually as required. The default setting is 6 digital inputs and 2 digital outputs. The
inputs and outputs can only be parameterized by IO-Link communication.
● Basic variant 6DI/2DO
6DI/2DO means that the variant has 6 digital inputs and 2 digital outputs. It is not possible
to change the number of inputs and outputs.
● Basic variant 4DI/4DO
4DI/4DO means that the variant has 4 digital inputs and 4 digital outputs. It is not possible
to change the number of inputs and outputs.
● Basic variant 2DI/6DO
2DI/6DO means that the variant has 2 digital inputs and 6 digital outputs. It is not possible
to change the number of inputs and outputs.
SIRIUS ACT 3SU1 pushbuttons and signaling devices
System Manual, 08/2018, A5E03457306020A/RS-AK/010
IO-Link 3SU14
12.3 Electronic modules for IO-Link
341