Type
Operating principle of the actuating
element
Product expansion, optional light source
Mechanical durability (operating cycles)
typical
Switching frequency maximum
Shock resistance
according to IEC 60068-2-27
Vibration resistance
according to IEC 60068-2-6
Degree of protection
Climate class in operation
according to EN 60721
Ambient temperature
during operation
•
during storage
•
with a relative air humidity of 10 to 95 %
1)
with non-illuminated variants
2)
SIRIUS ACT 3SU1 pushbuttons and signaling devices
System Manual, 08/2018, A5E03457306020A/RS-AK/010
3SU1..0-.AB
3SU1..0-.BB
3SU1..0-.CB
3SU1..0-.DB
3SU1..0-.JB
Momentary contact
No
10000000
1/h
3600
°C
°C
Technical specifications
3SU1..1-.AB
3SU1..1-.BB
3SU1..1-.JB
Yes
3000000
3600
11 ms, 50g, half-sine
10 ... 500 Hz: 5g
IP66, IP67, IP69
3K6
, 3C3
, 3S2, 3M6
1)
2)
-25 ... +70
-40 ... +80
14.2 Pushbuttons
3SU1..0-.HC
Momentary contact,
latching
No
1000000
1800
441