HBM FS22 SI User Manual page 61

Industrial braggmeter si
Table of Contents

Advertisement

FS22 SI
:ACQUisition:CONFiguration:RANGe:DELEte:C
Allows the user to delete the configuration of a single chan­
nel (using an integer value to define the channel C) or of all
the channels at once (using "A" to define all the channels).
Note: It is available only in state 2.
Example:
Command
Answer
:ACQUisition:CONFiguration:RANGe:ENABle
Enables the use of Ranges. Measurement method changes
from Conventional to Smart Peak Detection method (SPD).
Example:
Command
Answer
:ACQUisition:CONFiguration:RANGe:DISAble
Disables the use of Ranges. Measurement method changes
from Smart Peak Detection method (SPD) to the Conven­
tional.
Example:
Command
Answer
A4249-8.0 HBM: public
Remote Communications
:ACQU:CONF:RANG:DELE:A
:ACK
:ACQU:CONF:RANG:ENAB
:ACK
:ACQU:CONF:RANG:DISA
:ACK