Specifications; Outdoor Units - Daikin RXYQ96PYDN Service Manual

R-410a heat pump 60hz, r-410a heat recovery 60hz
Hide thumbs Also See for RXYQ96PYDN:
Table of Contents

Advertisement

SiUS34-801A_b

1. Specifications

1.1

Outdoor Units

Heat Pump 60Hz <RXYQ-PYDN> 460V
Model Name
Power Supply
1 Cooling Capacity
2 Heating Capacity
Casing Color
Dimensions: (H×W×D)
Heat Exchanger
Type
Piston Displacement
Number of Revolutions
Comp.
Motor Output×Number of
Units
Starting Method
Type
Motor Output
Fan
Air Flow Rate
Drive
Liquid Pipe
Connecting
Pipes
Gas Pipe
Mass
3 Sound Level (Reference Value)
Safety Devices
Defrost Method
Capacity Control
Refrigerant Name
Refrigerant
Charge
Control
Standard Accessories
Drawing No.
Notes:
VRVIII R-410A Heat Pump 60Hz
RXYQ72PYDN
3 Phase 60Hz 460V
Btu / h
72,000
Btu / h
81,000
Ivory White (5Y7.5/1)
66-1/8 × 36-5/8 × 30-1/8"
in(mm)
(1680 x 930 x 765 mm)
Cross Fin Coil
Hermetically Sealed Scroll Type
3
m
/h
10.53+13.34
r.p.m
(2900, 6300)
kW
(4.7) × 1
Soft Start
Propeller Fan
kW
(0.75) × 1
cfm
6,530
Direct Drive
3/8" (9.5 mm) C1220T
in(mm)
(Brazing Connection)
3/4" (19.1 mm) C1220T
in(mm)
(Brazing Connection)
Lbs (kg)
573 (260 kg)
dBA
High Pressure Switch, Fan Driver
Overload Protector, Overcurrent Relay,
Inverter Overload Protector
Deicer
%
20~100
R-410A
Lbs
Electronic Expansion Valve
Installation Manual, Operation Manual,
Connection Pipes, Cramps
4D058599B
1 Indoor temp. : 80°FDB or 67°FWB / outdoor temp. : 95°FDB / Equivalent piping length : 25 ft (7.5 m), level difference : 0 ft.
2 Indoor temp. : 70°FDB / outdoor temp. : 47°FDB or 43°FWB / Equivalent piping length : 25 ft (7.5 m), level difference : 0 ft.
3 Anechoic chamber conversion value, measured under JISB8616 conditions. During actual operation,
these values are normally somewhat higher as a result of ambient conditions.
3 Phase 60Hz 460V
Ivory White (5Y7.5/1)
66-1/8 × 36-5/8 × 30-1/8"
(1680 x 930 x 765 mm)
Hermetically Sealed Scroll Type
3/8" (9.5 mm) C1220T
(Brazing Connection)
7/8" (22.2 mm) C1220T
(Brazing Connection)
58
High Pressure Switch, Fan Driver
Overload Protector, Overcurrent Relay,
Inverter Overload Protector
18.1
Electronic Expansion Valve
Installation Manual, Operation Manual,
Connection Pipes, Cramps
RXYQ96PYDN
96,000
108,000
Cross Fin Coil
Hermetically Sealed Scroll Type
10.53+13.34
2900, 6300
(2.2+4.5) × 1
Soft Start
Propeller Fan
(0.75) × 1
6,530
Direct Drive
1-1/8" (28.6 mm) in C1220T
573 (260 kg)
58
High Pressure Switch, Fan Driver
Overload Protector, Overcurrent Relay,
Inverter Overload Protector
Deicer
14~100
R-410A
19.8
Electronic Expansion Valve
Installation Manual, Operation Manual,
Connection Pipes, Cramps
4D058600A
Specifications
RXYQ120PYDN
3 Phase 60Hz 460V
120,000
135,000
Ivory White (5Y7.5/1)
66-1/8 × 36-5/8 × 30-1/8"
(1680 x 930 x 765 mm)
Cross Fin Coil
10.53+13.34
2900, 6300
(3.5+4.5) × 1
Soft Start
Propeller Fan
(0.75) × 1
7,060
Direct Drive
1/2" (12.7 mm) C1220T
(Brazing Connection)
(Brazing Connection)
573 (260 kg)
60
Deicer
14~100
R-410A
20.1
4D058601A
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents