RXYQ72PYDN RXYQ216PYDN REYQ168PYDN RXYQ72PTJU RXYQ216PTJU REYQ168PTJU RXYQ96PYDN RXYQ240PYDN REYQ192PYDN RXYQ96PTJU RXYQ240PTJU REYQ192PTJU VRVIII System Operation RXYQ120PYDN REYQ72PYDN REYQ216PYDN RXYQ120PTJU REYQ72PTJU REYQ216PTJU air conditioner manual RXYQ144PYDN REYQ96PYDN REYQ240PYDN RXYQ144PTJU REYQ96PTJU REYQ240PTJU RXYQ168PYDN REYQ120PYDN RXYQ168PTJU REYQ120PTJU RXYQ192PYDN REYQ144PYDN RXYQ192PTJU REYQ144PTJU CONTENTS NOTE ....Indicates a situation that may result in the unit or property- 1.
Page 5
• Be sure to establish an earth. age to the equipment. Be sure only to use Do not earth the unit to a utility pipe, arrester, or accessories made by Daikin which are specif- telephone earth. ically designed for use with the equipment Incomplete earth may cause electrical shock, or fire.
Page 6
• Do not turn off the power immediately after [Place of Installation] stopping operation. • Make sure that the air conditioner is located in Always wait at least five minutes before turning off a sufficiently ventilated place not surrounded the power. Otherwise, water leakage and trouble by obstacles.
Low side (psig) 2. SPECIFICATIONS Model name RXYQ144PTJU RXYQ168PTJU RXYQ192PTJU Power supply [RXYQ] Phase — Frequency (Hz) Model name RXYQ72PYDN RXYQ96PYDN RXYQ120PYDN Voltage 208-230 208-230 208-230 Power supply Nominal cooling capacity (MBh) Phase — Nominal heating capacity (MBh) Frequency (Hz) (66-1/8×36-5/8×...
This operation manual is for the following system Nominal cooling capacity (MBh) with standard control. Before initiating operation, Nominal heating capacity (MBh) (66-1/8×36-5/ (66-1/8×36-5/ contact your Daikin dealer for the operation that cor- 8×30-1/8)+ 8×30-1/8)+ (66-1/8×36-5/ (66-1/8×36-5/ responds to your system type and mark.
Page 9
3. Display “ ” (changeover under control) 18. Temperature setting button It is impossible to changeover heat/cool with the Use this button for setting the desired temperature. remote controller which display this icon. Refer to the chapter “6-1 COOLING, HEATING, Refer to the chapter “6-5 SETTING THE MAS- AUTOMATIC AND FAN ONLY OPERATION”.
5. OPERATION RANGE NOTE Use the system in the following temperature and • Automatic operation (REYQ only) humidity ranges for safe and effective operation. In this operation mode, cool/heat changeover is automatically conducted. COOLING HEATING • The operation mode cannot be changed with outdoor temperature 23°~110°FDB 0°~60°FWB...
Page 11
Hot start NOTE • In order to prevent cold air from blowing out • For machine protection the system may con- of an indoor unit at the start of heating oper- trol the air flow rate automatically. ation, the indoor fan is automatically •...
Page 12
NOTE The operation lamp goes off and the system • The movable limit of the flap is changeable. stops operation. Contact your Daikin dealer for details. (Only for Multi-flow, Ceiling-suspended and Wall- NOTE mounted.) • Do not turn off the power immediately after •...
Page 13
6-4 PROGRAMMING START AND STOP OF 6-5 SETTING THE MASTER REMOTE CON- THE SYSTEM WITH TIMER TROLLER (Refer to figure 9) • In the case of the system as shown in figure 14, only the master remote controller can select oper- •...
The unit is individually operated. set temperature. We recommend starting the operation in advance NOTE using timer operation. • Contact your Daikin dealer in case of chang- ing the combination or setting of group control and two remote controller control systems. English...
• When the power is on, the unit consumes up to This is because cool/heat changeover is con- several dozen Watts of power. trolled by the cool/heat selector. Ask your Daikin Turn off the power to conserve energy. dealer where the remote control switch is installed.
Page 16
It is necessary to clean the inte- This is the noise of refrigerant caused by flow stop rior of the indoor unit. Ask your Daikin dealer for or flow change. details on cleaning the unit. This operation requires a qualified service person.
• This is to prevent oil and refrigerant from 4. Malfunction code remaining in the compressor. The unit will Measure: Notify your Daikin dealer and report the stop after 5 to 10 minutes. malfunction code. 9-14 THE INSIDE OF OUTSIDE UNIT IS...
• Check if the remote controller display shows • Repair after the warranty term is expired Contact your dealer. If necessary to repair, pay “ ” (time to clean the air filter); service is available. Refer to the operation manual of the indoor unit. And clean the air filter.
Page 19
Note 2 Note: Breakage due to taking apart or cleaning This maintenance cycle indicates recommended inside by anyone other than our authorized dealers lengths of time until the need arises for maintenance may not be included in the warranty. work, in order to ensure the product is operational ■...