Sign In
Upload
Manuals
Brands
Daikin Manuals
Heat Pump
VRV RXYQ72-384XAYCA
Daikin VRV RXYQ72-384XAYCA Manuals
Manuals and User Guides for Daikin VRV RXYQ72-384XAYCA. We have
1
Daikin VRV RXYQ72-384XAYCA manual available for free PDF download: Service Manual
Daikin VRV RXYQ72-384XAYCA Service Manual (419 pages)
Heat Pump 60 Hz
Brand:
Daikin
| Category:
Heat Pump
| Size: 11.11 MB
Table of Contents
Part 1 General Information
16
Table of Contents
16
1 Model Names
17
Outdoor Unit
17
Indoor Unit
18
Air Treatment Equipment
19
2 External Appearance
20
Outdoor Unit
20
Indoor Unit
21
Air Treatment Equipment
22
3 Combination of Outdoor Units
23
4 Capacity Range
24
Connection Ratio
24
Outdoor Unit Combinations
24
5 Specifications
25
Refrigerant Circuit Part 2
39
Refrigerant Circuit Part
40
1 Refrigerant Circuit (Piping Diagrams)
40
Outdoor Unit
40
Indoor Unit
44
Indoor Low-Temperature Hydrobox
47
Outdoor-Air Processing Unit
48
2 Functional Parts Layout
49
Rxyq72-120Xa, Rxyq72-120Xb
49
Rxyq144/168Xa, Rxyq144/168Xb
51
3 Refrigerant Flow for each Operation Mode
53
Cooling Operation
53
Heating Operation
54
Cooling Oil Return Operation
55
Defrost Heating Oil Return Operation
56
Part 3 Remote Controller
57
1 Applicable Models
58
2 Names and Functions
59
Brc1E73
59
Brc1H71W
62
Wireless Remote Controller
70
3 Main/Sub Setting
71
Brc1E73
71
Brc1H71W
73
When Wireless Remote Controller Is Used Together
75
4 Address Setting for Wireless Remote Controller
76
5 Centralized Control Group No. Setting
78
Brc1E73
78
Brc1H71W
80
Wireless Remote Controller
80
Group No. Setting Example
81
6 Service Settings Menu, Maintenance Menu
82
Brc1E73
82
7 Administrator Menu, Installer Menu
86
Brc1H71W
86
Part 4 Functions and Control
87
1 Operation Flowchart (Outdoor Unit)
89
2 Stop Control
90
Stop Due to Error
90
When System Is in Stop Control
90
Slave Unit Stops During Master Unit Control
90
3 Standby Control
91
Restart Standby
91
Crankcase Heater Control
91
4 Startup Control
92
Startup Control in Cooling
92
Startup Control in Heating
93
5 Basic Control
94
Normal Control
94
Compressor PI Control
95
Operating Priority and Rotation of Compressors
96
Compressor Step Control
97
Electronic Expansion Valve PI Control
99
Step Control of Outdoor Fans
100
6 Protection Control
101
High Pressure Protection Control
101
Low Pressure Protection Control
103
Discharge Pipe Protection Control
104
Compressor Body Protection Control
105
Inverter Protection Control
105
7 Special Control
107
Pump down Residual Operation
107
Oil Return Operation
107
Defrost Operation
109
Outdoor Unit Rotation
110
8 Other Control
111
Backup Operation
111
Demand Operation
111
Heating Operation Prohibition
111
9 Outline of Control (Indoor Unit)
112
Operation Flowchart
112
Set Temperature and Control Target Temperature
116
Remote Controller Thermistor
118
Thermostat Control
120
Drain Pump Control
123
Control of Electronic Expansion Valve
125
Freeze-Up Prevention Control
126
List of Swing Flap Operations
128
Hot Start Control (in Heating Operation Only)
129
Louver Control for Preventing Ceiling Dirt
130
Heater Control (Except FXTQ-TA, FXTQ-TB Models)
131
Heater Control (FXTQ-TA, FXTQ-TB Models)
132
Gas Furnace Control (CXTQ-TA Models)
135
3-Step Thermostat Processing (FXTQ-TA, FXTQ-TB Models)
136
Fan Control (Heater Residual) (FXTQ-TA, FXTQ-TB Models)
137
Interlocked with External Equipment (FXTQ-TA, FXTQ-TB, CXTQ-TA Models)
137
Part 5 Field Settings and Test Operation
139
1 Field Settings for Indoor Unit
140
Field Settings with Remote Controller
140
List of Field Settings for Indoor Unit
147
Detailed Explanation of Setting Modes
153
Field Settings of Low-Temperature Hydrobox
172
Gas Furnace Set up
172
List of Field Settings for Outdoor-Air Processing Unit
173
Operation Control Mode
173
2 Field Settings for Outdoor Unit
175
DIP Switch Setting When Mounting a Spare PCB
175
Accessing the BS Buttons on the PCB
177
Operating the BS Buttons and DIP Switches on the PCB
178
Connecting the PC Configurator to the Outdoor Unit
181
Monitoring Function and Field Settings
182
Night-Time Low Noise Operation and Demand Operation
204
Energy Saving and Optimum Operation
208
3 Test Operation
211
Checks before Test Operation
211
Checkpoints
211
Low-Temperature Hydrobox Test Operation
212
Gas Furnace Test Operation
212
Part 6 Service Diagnosis
213
1 Symptom-Based Troubleshooting
216
Indoor Unit Overall
216
Low-Temperature Hydrobox Overall
219
With Gas Furnace
219
Gas Furnace Lockout Reset
219
With Infrared Presence/Floor Sensor
220
2 Error Code Via Remote Controller
221
Brc1E73
221
Brc1H71W
222
Wireless Remote Controller
222
3 Troubleshooting by Error Code
224
Error Codes and Descriptions
224
Error Codes (Sub Codes)
226
External Protection Device Abnormality
236
Indoor Unit Control PCB Abnormality
238
Drain Level Control System Abnormality
239
Indoor Fan Motor Lock, Overload
241
Indoor Fan Motor Abnormality
243
Overload/Overcurrent/Lock of Indoor Fan Motor
249
Blower Motor Not Running
250
Indoor Fan Motor Status Abnormality
251
Low Indoor Airflow
252
Swing Flap Motor Abnormality
253
Power Supply Voltage Abnormality
255
Blower Motor Stops for Over/Under Voltage
256
Electronic Expansion Valve Coil Abnormality, Dust Clogging
257
Gas Furnace Abnormality
258
Drain Level above Limit
259
Self-Cleaning Decoration Panel Abnormality
260
Defective Capacity Setting
271
Transmission Abnormality between Indoor Unit Control PCB and Fan PCB
272
Blower Motor Communication Error
274
Climate Talk Communication Error
275
Thermistor Abnormality
276
Combination Error between Indoor Unit Control PCB and Fan PCB
277
Capacity Setting Abnormality
278
Blower Motor HP Mismatch
279
Indoor Blower Does Not Have Required Parameters to Function
280
Remote Sensor Abnormality
281
Infrared Presence/Floor Sensor Error
282
Remote Controller Thermistor Abnormality
287
Outdoor Unit Main PCB Abnormality
288
Detection of Ground Leakage by Leak Detection Circuit
289
Missing of Ground Leakage Detection Core
290
Activation of High Pressure Switch
291
Activation of Low Pressure Sensor
293
Compressor Motor Lock
294
Compressor Damage Alarm
296
Outdoor Fan Motor Abnormality
298
Electronic Expansion Valve Coil Abnormality
301
Discharge Pipe Temperature Abnormality
302
Wet Alarm
304
Refrigerant Overcharged
306
Harness Abnormality (between Outdoor Unit Main PCB and Inverter PCB)
307
Outdoor Fan PCB Abnormality
308
Thermistor Abnormality
309
High Pressure Sensor Abnormality
311
Low Pressure Sensor Abnormality
312
Inverter PCB Abnormality
313
Momentary Power Failure During Test Operation
315
Inverter Radiation Fin Temperature Rise Abnormality
316
Compressor Instantaneous Overcurrent
318
Compressor Overcurrent
320
Compressor Startup Abnormality
322
Transmission Error between Inverter PCB and Outdoor Unit Main PCB
324
Power Supply Voltage Imbalance
326
Inverter Radiation Fin Temperature Abnormality
328
Field Setting Abnormality after Replacing Outdoor Unit Main PCB or Combination of PCB Abnormality
330
Refrigerant Shortage
331
Reverse Phase, Open Phase
332
Power Supply Insufficient or Instantaneous Abnormality
333
Check Operation Not Executed
335
Transmission Error between Indoor Units and Outdoor Units, Open Phase in Power Supply Wiring
336
Transmission Error between Remote Controller and Indoor Unit
339
Transmission Error between Outdoor Units
340
Transmission Error between Main and Sub Remote Controllers
346
Transmission Error between Indoor Units and Outdoor Units in the same System
347
Improper Combination of Indoor Unit and Outdoor Unit, Indoor Unit and Remote Controller
348
Incorrect Gas Furnace Connecting Number
353
Incorrect Electric Heater Capacity Setting
354
Address Duplication of Centralized Controller
355
Transmission Error between Centralized Controller and Indoor Unit
356
System Not Set yet
359
System Abnormality, Refrigerant System Address Undefined
360
Climate Talk Communication System Combination Error (before Initial Setting for Communication Completes)
362
Climate Talk Communication System Combination Error (after Initial Setting for Communication Completes)
363
4 Check
364
High Pressure Check
364
Low Pressure Check
365
Superheat Operation Check
367
Power Transistor Check
369
Refrigerant Overcharge Check
370
Refrigerant Shortage Check
371
Vacuuming and Dehydration Procedure
372
Thermistor Check
373
Pressure Sensor Check
376
Broken Wire Check of the Relay Wires
377
Fan Motor Connector Check (Power Supply Cable)
379
Fan Motor Connector Check (Signal Cable)
381
Electronic Expansion Valve Coil Check
383
Fan Motor Connector Check for FXTQ-TA, FXTQ-TB
386
Wiring Diagrams
391
Outdoor Unit
391
Indoor Unit
393
Air Treatment Equipment
416
Advertisement
Advertisement
Related Products
Daikin VRV RXYQ72-384XBYCA
Daikin RXYQ72-408TAYDU
Daikin RXYQ72-408TATJU
Daikin RXYQ72TAYDU
Daikin RXYQ72TATJU
Daikin RXYQ72TAYCU
Daikin VRV IV RXYQ72TAYCA
Daikin VRV EMERION RXYQ72AATJA
Daikin VRV EMERION RXYQ72AAYDA
Daikin RXYQ34PYLE
Daikin Categories
Air Conditioner
Heat Pump
Remote Control
Chiller
Fan
More Daikin Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL