Measurement On Narrow Targets - MICRO-EPSILON capaNCDT 6200 Operating Instructions Manual

Hide thumbs Also See for capaNCDT 6200:
Table of Contents

Advertisement

Appendix| Measurement on Narrow Targets
A 4
Fig. 33 Example of measuring range deviation in the
case of a sensor distance of 10 % of the measuring
range
Fig. 35 Example of measuring range deviation in the
case of a sensor distance of 100 % of the measu-
ring range
capaNCDT 6200

Measurement on Narrow Targets

50 %
45 %
40 %
35 %
30 %
25 %
20 %
15 %
10 %
5 %
0 %
0
0.5
1
1.5
Target dispacement perpendicular to the sensor axis [mm]
50 %
45 %
40 %
35 %
30 %
3 mm
25 %
4 mm
20 %
15 %
10 %
5 %
0 %
0
0.5
1
1.5
Target dispacement perpendicular to the sensor axis [mm]
50 %
45 %
40 %
35 %
30 %
25 %
20 %
3 mm
15 %
4 mm
10 %
6 mm
5 %
8 mm
0 %
2
2.5
3
Fig. 34 Example of measuring range deviation in the
case of a sensor distance of 50 % of the measuring
range
6 mm
8 mm
2
2.5
3
Fig. 36 Signal change in the case of displacement of
thin targets in the opposite direction to the measure-
ment direction
3 mm
4 mm
6 mm
0
0.5
1
1.5
Target dispacement perpendicular to the sensor axis [mm]
y
y >8 mm
8 mm
2
2.5
3
z
z constant
x
Movement
in x-direction