Table of Contents
Table of Contents
3
1 Safety
5
Symbols Used
5
Warnings
5
Notes on CE Marking
5
Intended Use
6
Proper Environment
6
2 Functional Principle, Technical Data
7
Measuring Principle
7
Structure
7
Sensors
8
Sensor Cable
9
Preamplifier (DL6510 Only)
9
Preamplifier Cable (DL6510 Only)
9
Controller Housing
10
Oscillator
10
DD6500 Display Board with Ethernet Interface
11
Demodulator
11
Technical Data
12
3 Delivery
13
Unpacking
13
Storage
13
4 Installation and Assembly
14
Precautionary Measures
14
Sensor
14
Radial Point Clamping with Grub Screw, Cylindric Sensors
14
Circumferential Clamping, Cylindric Sensors
14
Flat Sensors
14
Dimensional Drawing Sensors
15
Sensor Cable
18
Preamplifier CP6001 and CPM6011
19
Preamplifier Cable Cax
20
Controller
20
Power Supply
21
Ground Connection, Earthing
21
Pin Assignment
22
Synchronization
23
5 Operation
24
Starting up
24
Basic Settings
24
Dt6530
24
Dd6530
24
Do6510
25
Dl6530/6510
26
Calibration with Metal Targets
28
Linearity Adjustment and Calibration with Insulator Targets
29
Triggering
31
Synchronization
31
6 Ethernet Interface
32
Hardware, Interface
32
Data Format of Measuring Values
34
Settings
34
Commands
35
Data Rate (SRA = Set Sample Rate)
36
Trigger Mode (TRG)
36
Get Measured Data (GMD)
37
Averaging Type (AVT)
37
Dynamic Noise Rejection
38
Averaging Number (AVN)
38
Channel Status (CHS)
38
Channel Transmit (CHT)
38
Mode of Linearization (LIN)
39
Set Linearization Point (SLP)
39
Get Linearization Point (GLP)
40
Status (STS)
40
Version (VER)
40
Display Setups (DIS)
40
Capancdt
40
Load Factory Setting (FDE)
41
SMF = Set Mathematic Function (SMF)
41
Get Mathematic Function (GMF)
42
Clear Mathematics Function (CMF )
42
Ethernet Settings (IPS = IP-Settings)
42
Change between Ethernet and Ethercat (IFC = Interface)
42
Query Data Port (GDP = Get Dataport)
43
Set Data Port (SDP = Set Dataport)
43
Access Channel Information (CHI = Channel Info)
43
Access Controller Information (COI = Controller Info)
43
Login for Web Interface (Lgi = Login)
43
Logout for Web Interface (LGO = Logout)
43
Change Password (PWD = Password)
44
Change Language for the Web Interface (LNG = Language)
44
Write Measuring Range Information in Channel (MRA = Measuring Range)
44
6.4.30 Default Messages
44
Operation Using Ethernet
45
Requirements
45
Access Via Web Interface
46
Firmware Update
46
7 Ethercat Interface
46
Introduction
46
Change Interface
47
8 Operation and Maintenance
47
9 Liability for Material Defects
48
10 Decommissioning, Disposal
48
A 1 Optional Accessory
49
A 2 Services
51
Factory Setting
51
A 4 Tilt Angle Influence on the Capacitive Sensor
51
A 4.1 Measurement on Narrow Targets
51
A 4.2 Measurements on Balls and Shafts
52
Ethercat Documentation
53
Preamble
53
A 5.1.1 Structure of Ethercat®-Frames
53
A 5.1.2 Ethercat® Services
53
A 5.1.3 Addressing and Fmmus
54
A 5.1.4 Sync Manager
54
A 5.1.5 Ethercat State Machine
55
A 5.1.6 Canopen over Ethercat
55
A 5.1.7 Process Data PDO Mapping
55
A 5.1.8 Service Data SDO Service
56
A 5.2 Coe - Object Directory
56
A 5.2.1 Communication Specific Standard Objects (Cia DS-301)
56
A 5.2.2 Manufacturer Specific Objects
57
A 5.3 Measurement Data Format
60
A 5.4 Ethercat Configuration with the Beckhoff Twincat©-Manager
60
A 6 Thickness Measurement
63
A 6.1 General
63
A 6.2 Define Sensor Measuring Ranges
63
A 6.3 Data Format, Word Length
64
A 6.4 Set Math Functions
64
A 6.5 Interpretation of the Measuring Values
65
A 6.6 Example
65
Capancdt
66
Advertisement
MICRO-EPSILON capaNCDT 6500 Operating Instructions Manual (68 pages)
Brand:
MICRO-EPSILON
| Category:
Measuring Instruments
| Size: 8 MB
Table of Contents
Table of Contents
3
Safety
5
Symbols Used
5
Warnings
5
Notes on CE Marking
5
Intended Use
6
Proper Environment
6
Functional Principle, Technical Data
7
Measuring Principle
7
Structure
7
Sensors
8
Sensor Cable
9
Preamplifier (DL6510 Only)
9
Preamplifier Cable (DL6510 Only)
9
Controller Housing
10
Oscillator
10
DD6500 Display Board with Ethernet Interface
11
Demodulator
11
Technical Data
12
Delivery
13
Unpacking
13
Storage
13
Installation and Assembly
14
Precautionary Measures
14
Sensor
14
Radial Point Clamping with Grub Screw, Cylindric Sensors
14
Circumferential Clamping, Cylindric Sensors
14
Flat Sensors
14
Dimensional Drawing Sensors
15
Sensor Cable
19
Preamplifier CP6001 and CPM6011
20
Preamplifier Cable Cax
21
Controller
21
Power Supply
22
Ground Connection, Earthing
22
Pin Assignment
23
Synchronization
24
Operation
25
Initial Operation
25
Basic Settings
25
Dt6530
25
Dd6530
25
Do6510
26
Dl6530/6510
27
Calibration with Metal Targets
29
Linearity Adjustment and Calibration with Insulator Targets
30
Triggering
32
Synchronization
32
Ethernet Interface
33
Hardware, Interface
33
Data Format of Measuring Values
35
Settings
35
Commands
36
Data Rate (SRA = Set Sample Rate)
37
Trigger Mode (TRG)
37
Get Measured Data (GMD)
38
Averaging Type (AVT)
38
Dynamic Noise Rejection
39
Averaging Number (AVN)
39
Channel Status (CHS)
39
Channel Transmit (CHT)
39
Mode of Linearization (LIN)
40
Set Linearization Point (SLP)
40
Get Linearization Point (GLP)
41
Status (STS)
41
Version (VER)
41
Display Setups (DIS)
41
Load Factory Setting (FDE)
42
SMF = Set Mathematic Function (SMF)
42
Get Mathematic Function (GMF)
43
Clear Mathematics Function (CMF )
43
Ethernet Settings (IPS = IP-Settings)
43
Change between Ethernet and Ethercat (IFC = Interface)
43
Query Data Port (GDP = Get Dataport)
44
Set Data Port (SDP = Set Dataport)
44
Access Channel Information (CHI = Channel Info)
44
Access Controller Information (COI = Controller Info)
44
Login for Web Interface (Lgi = Login)
44
Logout for Web Interface (LGO = Logout)
44
Change Password (PWD = Password)
45
Change Language for the Web Interface (LNG = Language)
45
Write Measuring Range Information in Channel (MRA = Measuring Range)
45
6.4.30 Default Messages
45
Control Via Ethernet
46
Requirements
46
Access Via Web Interface
47
Firmware Update
47
Ethercat Interface
47
Introduction
47
Change Interface
48
Operation and Maintenance
48
Liability for Material Defects
49
Decommissioning, Disposal
49
A 1 Optional Accessory
50
A 2 Services
52
Factory Setting
52
A 4 Tilt Angle Influence on the Capacitive Sensor
52
A 4.1 Measurement on Narrow Targets
52
A 4.2 Measurements on Balls and Shafts
53
A 5 Ethercat Documentation
54
A 5.1 Preamble
54
A 5.1.1 Structure of Ethercat®-Frames
54
A 5.1.2 Ethercat® Services
54
A 5.1.3 Addressing and Fmmus
55
A 5.1.4 Sync Manager
55
A 5.1.5 Ethercat State Machine
56
A 5.1.6 Canopen over Ethercat
56
A 5.1.7 Process Data PDO Mapping
56
A 5.1.8 Service Data SDO Service
57
A 5.2 Coe - Object Directory
57
A 5.2.1 Communication Specific Standard Objects (Cia DS-301)
57
A 5.2.2 Manufacturer Specific Objects
58
A 5.3 Measurement Data Format
61
A 5.4 Ethercat Configuration with the Beckhoff Twincat©-Manager
61
A 6 Thickness Measurement
64
A 6.1 General
64
A 6.2 Define Sensor Measuring Ranges
64
A 6.3 Data Format, Word Length
65
A 6.4 Set Math Functions
65
A 6.5 Interpretation of the Measuring Values
66
Example
66
Advertisement
Related Products
MICRO-EPSILON capaNCDT 6100
MICRO-EPSILON capaNCDT 6114
MICRO-EPSILON capaNCDT 6124
MICRO-EPSILON capaNCDT 6114/5
MICRO-EPSILON capaNCDT 6114/15
MICRO-EPSILON capaNCDT 6124/5
MICRO-EPSILON capaNCDT 6124/15
MICRO-EPSILON capaNCDT 6200
MICRO-EPSILON capaNCDT 6630
MICRO-EPSILON capaNCDT 6240
MICRO-EPSILON Categories
Measuring Instruments
Accessories
Industrial Equipment
Controller
Security Sensors
More MICRO-EPSILON Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL