Distance Measurement Without Reflectors (Non-Prism Mode) - Leica FlexLine plus User Manual

Hide thumbs Also See for FlexLine plus:
Table of Contents

Advertisement

17.3
Range
Atmospheric
conditions
Accuracy
Characteristics
Laser dot size
FlexLine plus, Technical Data

Distance Measurement without Reflectors (Non-Prism mode)

Power Pinpoint R500 (without reflector)
Kodak Gray Card
White side, 90 % reflective
Grey side, 18 % reflective
Ultra Pinpoint R1000 (without reflector)
Kodak Gray Card
White side, 90 % reflective 800
Grey side, 18 % reflective
Range of Measurement:
Display unambiguous:
Range D:
Object in strong sunlight, severe heat shimmer
Range E:
Object in shade, or overcast
Range F:
Underground, night and twilight
Valid for
and
.
Standard
ISO 17123-4
measuring
0 m - 500 m
2 mm + 2 ppm
>500 m
4 mm + 2 ppm
Beam interruptions, severe heat shimmer and moving objects within the beam path
can result in deviations of the specified accuracy.
Tracking measuring*
Tracking
* Accuracy and measure time depend on atmospheric conditions, target object and
observation situation.
Type:
Carrier wave:
Measuring system:
Distance [m]
at 30
at 50
at 100
Range D
Range E
[m]
[ft]
[m]
250
820
400
100
330
150
Range D
Range E
[m]
[ft]
[m]
2630
1000
400
1320
500
1.5 m to 1200 m
up to 1200 m
Measure time,
typical [s]
3 - 6
3 - 6
Standard deviation
5 mm + 3 ppm
Coaxial, visible red laser
658 nm
System analyser basis 100 MHz - 150 MHz
Distance measurement system using phase-shift prin-
ciple with frequency 320 MHz
Laser dot size, approximately [mm]
7 x 10
8 x 20
16 x 25
Range F
[ft]
[m]
[ft]
1312
>500
>1640
490
>250
>820
Range F
[ft]
[m]
[ft]
3280
>1000
>3280
1640
>500
>1640
Measure time,
maximum [s]
15
15
Measure time, typical [s]
0.25
1.00
169