Technical Data; Angle Measurement; Distance Measurement With Reflectors - Leica FlexLine plus User Manual

Hide thumbs Also See for FlexLine plus:
Table of Contents

Advertisement

17
17.1
Accuracy
Characteristics
17.2
Range
Atmospheric
conditions
FlexLine plus, Technical Data

Technical Data

Angle Measurement

Available angular
accuracies
["]
1
2
3
5
7
Absolute, continuous, diametric. Updates each 0.1 to 0.3 s.

Distance Measurement with Reflectors

Reflector
Standard prism (GPR1)
3 prisms (GPR1)
360° prism (GRZ4, GRZ122)
Reflector tape 60 mm x 60 mm
Prism mode
Non-prism mode, R500
Non-prism mode, R1000
Mini prism (GMP101)
360° Mini prism (GRZ101)
Shortest measuring distance:
Range A:
Strong haze, visibility 5 km; or strong sunlight, severe heat shimmer
Range B:
Light haze, visibility about 20 km; or moderate sunlight, slight heat
shimmer
Range C:
Overcast, no haze, visibility about 40 km; no heat shimmer
Standard deviation
Hz, V, ISO 17123-3
[mgon]
0.3
0.6
1.0
1.5
2
Range A
[m]
[ft]
1800
6000
2300
7500
2300
7500
800
2600
150
500
300
1000
600
1950
800
2600
450
1500
1.5 m
Display resolution
["]
[°]
[mgon]
0.1
0.0001
0.1
0.1
0.0001
0.1
0.1
0.0001
0.1
0.1
0.0001
0.1
0.1
0.0001
0.1
Range B
Range C
[m]
[ft]
[m]
3000
10000
3500
3000
10000
3500
4500
14700
5400
1500
5000
2000
250
800
250
500
1600
>500
1000
3300
>1000 >3300
1200
4000
2000
800
2600
1000
[mil]
0.01
0.01
0.01
0.01
0.01
[ft]
12000
12000
17700
7000
800
>1600
7000
3300
167