Leica FlexLine Frequently Asked Questions Manual
Hide thumbs Also See for FlexLine:
Table of Contents

Advertisement

Quick Links

Leica FlexLine & FlexLine plus
Frequently Asked Questions (FAQ)

Advertisement

Table of Contents
loading

Summary of Contents for Leica FlexLine

  • Page 1 Leica FlexLine & FlexLine plus Frequently Asked Questions (FAQ)
  • Page 2: Table Of Contents

    Datalogger: Which Datalogger can I connect to the FlexLine instrument ?.............. 10 1.32 Datalogger: How do I setup a Bluetooth connection from Datalogger to the FlexLine instrument? ....... 10 1.33 Leica Viva: Does the Leica Viva Software supports FlexLine instruments ? .............. 10 1.34...
  • Page 3 Communication Sidecover: Why is no USB stick and cable included anymore? ............12 2.16 Firmware: Can I upload the new FlexField plus Firmware onto my existing FlexLine instrument? ......12 2.17 Firmware: Is the TS09plus firmware another one as the TS02 firmware ? .............. 12 2.18...
  • Page 4 FlexOffice: Why is FlexOffice Standard not free of charge like Leica Geo Office Tools? .......... 17 3.10 FlexOffice: Is it possible to load my own format templates for the export/import of ASCII data? ......17 3.11 FlexOffice: How do I get a ASCII coordinate file (e.g. csv or txt file) into FlexOffice and to the instrument ? ..17 3.13...
  • Page 5: Flexline General

    FlexLine General 1.1 FlexLine – What Product belong to the FlexLine family? FlexLine products are Total Stations of the TS02, TS06 and TS09 and newly TS06plus and TS09plus family. 1.2 Online Commands: Which online commands does FlexLine support? FlexLine supports GSI as well as GeoCom commands. Documentation can be found on the instrument CD in the TOOLS folder.
  • Page 6: Bluetooth: Which Bluetooth Class You Are Using

    In some cases Leica total stations are locally certified to be used in explosive environments if the mainboard was sealed, in other cases a warning sticker not to remove the battery had to be placed on the instrument.
  • Page 7: Downgrade-Function: Can I Downgrade The Instrument By Software - Is This True And How Does It Work

    2. Set “End Demo” at the instrument (Tools_ License Keys _ F2) 3. Upload the key file you received when ordering the 90 days SW maintenance key. 4. Upload the latest firmware (available from the Leica website) FAQ - FlexLine plus V.4.5.doc...
  • Page 8: Can I Order The Free Of Charge 90 Days Sw Maintenance Key For Any Instrument

    Exchange Manager, Software Upload) and for Service and Production processes. To use ActiveSync program to directly explore data stored on the instrument is not beneficial as those data are in a different format and cannot be used directly. FAQ - FlexLine plus V.4.5.doc Page 8/18...
  • Page 9: Active Sync: How Do I Setup A Connection Between The Pc And The Total Station With The Usb Cable

    1. Install Microsoft Active Sync if you using Windows XP or in case you are using Windows Vista the install Microsoft Mobile Device Center Both programs are available at the Microsoft webpage or on the Leica download Area or on the TPS instruments CD coming along with each FlexLine Total Station (Folder:..\Tools\Microsoft\) 2.
  • Page 10: Datalogger: Which Datalogger Can I Connect To The Flexline Instrument

    2. On the Datalogger you can then select to "PAIR" the devices and then you will be asked to enter a Bluetooth PIN. The Bluetooth PIN of the FlexLine is configurable, but by default set to "0000". Enter the PIN and proceed.
  • Page 11: Flexline Plus

    FlexLine plus 2.1 FlexLine plus – what is new on it ? The TS06 plus is available as 1", 2", 3", 5", 7" variants, both as power (R500) models and ultra (R1000) models. Note that we have added 1" and 7" variants and that there are no non-reflectorless ("TC-") models available anymore.
  • Page 12: Ts02Plus: Is The Spot Size The Same As With The Ergofocus Telescope

    2.19 Firmware: Is it “Viva-light” running on the TS09plus ? No, on all FlexLine /plus total stations the “FlexField plus” firmware is installed. Even though the design of the icons look very similar to the Viva icons, the firmware is completely different.
  • Page 13: My Security" - How Does It Work

    Yes, this is possible by installing onboard firmware version 3.0 or higher. However please note that the protection level is not as high as with FlexLine plus units, as it is possible to load older firmware that this mechanism does not support. On FlexLine plus total stations it is not possible to upload older firmware versions than 3.0...
  • Page 14: User Logo

    2.31.2 Is it possible to convert existing b& w logos to Logos for the Colour-& Touchscreen ? No, please provide me new logo files for the use on the colour screen. 2.31.3 User Logo: Can I upload my existing b&w logo to FlexLine plus instrument ? Yes.
  • Page 15: Screensaver: Is It Possible To Change The Screensaver Contents

    The FlexLine supported colour-palette can be requested when contacting Surveying.Support@leica- geosystems.com . To apply the colour palette you need to open a image-program (Photoshop, Irfan View,…), open the image that should be converted and then load the colour palette. Then save the image...
  • Page 16: Flexoffice

    FlexOffice: Why are there two different versions of FlexOffice? One of the main features of FlexLine is the scalability of the products. The same idea is applied to the FlexOffice with its two versions. The choice is always yours.
  • Page 17: Flexoffice: Can I Run Flexoffice With My Existing Lgo-Demo-Key

    FlexOffice: Can I run FlexOffice with my existing LGO-Demo-Key? Yes. FlexOffice: Why is FlexOffice Standard not free of charge like Leica Geo Office Tools? First of all, there needs to be an awareness created that software should not be considered a “Free of Charge Article”...
  • Page 18 (PC section) and moving it to the right side of the window (TS- section) 3.13 FlexOffice: Is it possible to upgrade my FlexOffice Standard licence to FlexOffice Advanced? This is not possible. You need to purchase FlexOffice Advanced separately. FAQ - FlexLine plus V.4.5.doc Page 18/18...

This manual is also suitable for:

Flexline plus

Table of Contents