Measure traverse -
Sight Backsight!
Measure traverse -
Sight Foresight!
Interrupt a set
Continue with...
Repetitive loop for
the number of sets
FlexLine plus, Programs
Field
Description
Point ID of the backsight point.
BS ID
Remark
Description of the backsight point.
Stat.ID
Name of the station.
Next step
Depending on the traverse method configured, after the measurement either the
Sight Backsight! screen stays active for measuring the backsight point in a second
face, or the Sight Foresight! screen appears for measuring the foresight point.
Next step
Depending on the traverse method configured, after the measurement either the
Sight Foresight! screen stays active for measuring the foresight point in a second
face, or the Sight Backsight! screen appears for measuring the backsight point.
To interrupt a set, press ESC to exit the backsight or foresight screen. The Continue
with... screen will appear.
Field
Description
F1 Redo last
Returns to last measured point, can be either a backsight or a
measurement
foresight point. The last measurement is not stored.
Returns to first sight point screen. The data from the last station
F2 Redo whole
is not stored.
station
Returns to the Programs Menu. The traverse stays active and
F3 Exit Traverse
can be continued later. The data from the last station is lost.
Returns to the previous screen where ESC was pressed.
F4 Back
Alternating between screens for the backsight and foresight measurements continues
according to the configured number of sets.
The number of sets and the face are indicated in the top right corner of the screen.
For example 1/I means set 1 in face I.