Starting And Configuring Traverse - Leica FlexLine plus User Manual

Hide thumbs Also See for FlexLine plus:
Table of Contents

Advertisement

7.14.2
Access
Traverse
configuration
Measure Traverse -
Enter Station Data
Next step
FlexLine plus, Programs

Starting and Configuring Traverse

1.
Select
Programs from the Main Menu.
2.
Select
Traverse from the Programs Menu.
3.
Complete program pre-settings.
• F1 Set Job:
Only one traverse per job is allowed. If an adjusted or finished traverse is
already part of the selected job, then select another job. Refer to "6 Programs
- Getting Started".
• F2 Set Tolerances:
Use Tolerances: Yes to activate the use of tolerances.
Enter limits for horizontal direction (the difference between measured and
calculated azimuth to the closing point), distance (the distance between
known and measured closing point), and for differences in Easting, Northing
and Height. If the adjustment results, or the deviation for a check point, exceed
these limits a warning message appears.
Press Cont to save the limits and return to the Pre-settings screen.
4.
Select F4 Start to begin the program.
It is not recommended to start a traverse if the memory is almost full. Doing so, may
mean the traverse measurements and results cannot be saved. Accordingly, a message
is displayed if less than 10% of the memory is free.
Field
Description
Name of the new traverse.
Traverse ID
Description, if desired.
Desc.
Name of the user who will be using the new traverse, if desired.
Operator
Method
B'F'F"B"
B'B"F"F'
B'F'
Number of sets. Limited to 10.
No. of Sets
Use Face-Tol. Important when measuring with face I and II. This checks if both meas-
urements are within a defined limit. If the limit is exceeded, a warning
message is displayed.
Face-Tol.
The limit that will be used for checking the face tolerance.
Next step
Press Cont to confirm the traverse configuration and proceed to the Enter Station
Data screen.
Field
Description
Name of the station.
Stat.ID
hi
Height of the instrument.
Desc.
Description of the station, if desired.
Every Traverse must start on a known point.
Press Cont to confirm station data and proceed to the Traverse - Select screen.
All points are measured in face I, then all points are meas-
ured in face II in reverse sequential order.
The backsight point is measured in face I immediately
followed by face II. Other points are measured in alter-
nating face order.
All points are measured in face I only.