How to Record the Data
(6) When "Diagnosis Code Trigger" is selected in (5), the left
screen appears.
• Select an item to be the trigger, and press
-- to (8). (If Threshold Trigger is selected as well, go to (7))
(7) When "Threshold Trigger" is selected in (5), the left screen
appears.
• Select an item and edit conditions in Condition Editing table
appearing at the bottom of the screen, first.
Condition Editing table
"UP/DOWN": Threshold or higher / Threshold or lower
"Level/Edge": Matching data / Data as of the time when it turns
to be matching from not matching
"AND/OR":- Data matching with both of this condition and the
other one upper row on Condition of Trigger table /
-Data matching with either of this condition or the
other one upper row on Condition of Trigger table
• Then, press
area of Condition of Trigger table.
(Condition of Trigger table can include up to 8 conditions.)
• When completed the setting, press
(8) Select the V.C.I. recording area on the left list.
Set the sampling interval and rate distributions (before and
after trigger) by moving the cursor or by pressing
button.
--OK -- to (10)
--Display of V.C.I. data -- to (9)
Note:
-You can select from eight recording areas.
-It is possible to set consecutive areas as well.
-The sampling interval time indicates the data-recording
interval for one item. A setting of 0 seconds results in the
fastest sampling interval.
-When a sampling interval other than the fastest interval is
selected, the amount of time in which recording is possible
appears. This time is a calculated estimated time and may
differ from the actual amount.