Data List
(2) Record Data
1. Graph data is paused by pressing
data can be saved on the PC automatically.
-- OK -- to 2
--Cancel (Not save the data and return to the pause
screen. Pressing
2. The data has been saved.
The file name of the recorded data is set as
"SD + YearMonthDay + Time (military time including
seconds)", using the PC time as standard.
-- OK
Note:
For details on how to view the saved data, refer to 6-2-2(3).
(3) Changing Item Display Order
-On the data list display screen, you can change the display
order of the items. The change is possible for both text
display and graph display.
-The display order change can be performed with the data
list displayed continuously. (The graph display is reset.)
-Selecting the name display area of an item fixes the item.
Then over-scrolling only the items not selected using the
vertical scroll keys changes the order.
-The selection can be released by selecting the item again.
-The function is not activated while a data range display
area is selected. (Selection, release, and scroll functions of
item are not available.)
(4) Data Range Change
-Select a data range display area on the graph.
-When the color of the selected area turns into yellow, you
can enter values.
-Entering method: Use PC keyboard or scroll keys.
-When use PC keyboard, enter a value, and then press the
[Enter] key or release the selection of the data range
display area to determine the data range change.
-When the scroll keys,
for the data range change, pressing the
changes the data range setting by +5 % of full scale and
the . key changes it by −5 %. The change is determined
at each key pressing.
26
button, and the
button starts data list again.)
and
, on the screen are used
key each time