Data List
4-2-2. Details of Data List Screen
(1) Displaying Item Selection
• Item Group Select
Select a group of the data to be displayed,
and press
• Item Select
By default, none of the items are selected.
Select an item that you wish to display, and apply the
selection using
--Inserts all the items from "Available item list" into the
selection areas of "Selected item list."
--Inserts the item selected in "Available item list" into the
selection area of "Selected item list".
--Inserts the item selected in "Selected item list" into the
lowermost area of "Available item list".
--Inserts all the items from "Selected item list" into the
lowermost areas of "Available item list."
--Changes the order in which the items are displayed in
the "Selected item list" and the "Available item list," in
the sequence of default setting.
When complete the selection, press
Note:
-When there is no selected item, all items are displayed.
-The column of item No appears in green when the service
data is OBD basic items.
-"Fuel pressure" and "Voltmeter" cannot be selected
simultaneously.
When you select the item "Fuel pressure"
1. Pressure gauge list will be displayed after item selection.
Select a type of pressure gauge used for fuel pressure
measurement, and press
2. Set up the calibration voltage of the pressure gauge, and
press
Note:
For details on how to measure calibration voltage, refer
to 11-3-1(1).
25
button.
or
buttons.
button.
button.
button.