Mitsubishi MOTORS M.U.T.-III Owner's Manual page 114

Multi use tester
Hide thumbs Also See for M.U.T.-III:
Table of Contents

Advertisement

Fuel pressure, Voltage, Ohmmeter, Oscilloscope
11-3-2. Measuring Voltage and Resistance
(1) Press
11-3-3. Oscilloscope Function
(1) Press Oscilloscope on the menu screen of 11-1-1(1).
(2) Setting the Time Axis and Voltage Axis
Voltmeter
screen of 11-1-1(1).
The voltage or resistance value comes from the test leads
connected to the trigger terminal and displayed on the PC
screen.
-For details on how to connect the measurement probe,
and details for measuring using V.C.I. alone, refer to
2-2-3.
-Prior to executing the measurement process, calibrate
the instrument to 0 using
Note:
-DC voltage can be measured in the range of 0-±40V.
-Resistance can be measured in the range of 0-100KΩ.
This function allows you to observe the continuous
waveform, which is loaded from the voltage measurement
terminal, on PC screen using test leads (MB991499, etc).
--Starts the waveform display
--Stops the waveform display
--Switches to Scale mode
: to set the time axis and voltage axis -- (2)
--Switches to Trigger mode
: to set trigger conditions -- (3)
Note:
DC voltage can be measured in the range of 0-±40V, and
resolution can be measured at 0.1V.
The shortest sampling interval is 500µs.
button switches to the scale mode, and the
buttons can be used to set time axis and voltage axis.
--Changes time axis scale
--Changes voltage axis scale
Note:
Time scale:
(10,20,40,100ms/div)
Voltage scale: (1,2,5,8V/div)
107
or
Ohmmeter
on the menu
button.