Device firmware upgrade

The Rosemount TankMaster WinSetup program allows you to upgrade the Rosemount 2410 Tank Hub
and other devices in a Rosemount Tank Gauging system with new firmware.
Note
In case the current firmware version is significantly older than the new one, it is recommended that you
load the default configuration database once the device is reprogrammed. Contact Emerson
Automation Solutions/Rosemount Tank Gauging service department if you need further advice.
To upgrade a device with new firmware do the following:
1. Ensure that the latest versions of *.ini-files are installed on the TankMaster PC. New *.ini files can
easily be installed by running the TankMaster setup program located in the DeviceIniFiles folder on
the TankMaster installation CD.
2. Ensure that the Rosemount 2410 Tank Hub communicates with TankMaster without any interruptions
or disturbances.
3. In the TankMaster WinSetup workspace window (Logical View) open the Devices folder and select the
icon that represents the tank hub to be upgraded (or select the Devices folder to allow multiple
devices programming).
4. Click the right mouse button and choose the Program option (Program All option for multiple
devices programming).
5. The tank hub will automatically appear in the Program These Devices pane.
6. In case you wish to upgrade several tank hubs simultaneously, you may use the multiple
programming options:
Service and Troubleshooting