Other Memory Error
Sys Error
Display Error
Aux Error
FF Stack Error
Tankbus Communication Error
Host Communication Error
Data Manager Error
Configuration Error
106
Message
Description
Input register no. 6108:
Bit 0: CheckSum
Bit 1: Stack
Input register no. 6110.
Bit 0: Task Supervisor
Input register no. 6112.
Bit 0: Hardware
Bit 1: Com
Bit 2: Configuration
Input register no. 6114.
Bit 0: Internal temperature out of
limits
Bit 1: Internal temp measurement
failed
Bit 2: Internal temperature device
failed
Bit 3: Relay 1
Bit 4: Relay 2
Bit 5: Power
Input register no. 6116.
Input register no. 6118.
Bit 0: Unknown device connected to
the Tankbus
Input register no. 6120.
Bit 1: Hardware Primary modem
Bit 2: Hardware Secondary modem
Bit 3: Illegal Primary modem
Bit 4: Illegal Secondary modem
Input register no. 6122.
Bit 1: Tank configuration
Input register no. 6124.
Reference Manual
00809-0100-2410, Rev DA
Action
Contact Emerson Automation
Solutions/Rosemount Tank Gauging
service department