Write Protection - Emerson Rosemount 2410 Reference Manual

Tank hub
Hide thumbs Also See for Rosemount 2410:
Table of Contents

Advertisement

Reference Manual
00809-0100-2410, Rev DA
6.2.8

Write protection

A Rosemount 2410 Tank Hub can be write protected to avoid unintentional configuration changes when
using the TankMaster programs. To write protect the Rosemount 2410:
1. Start the TankMaster WinSetup program.
2. In the WinSetup workspace select the Logical View tab.
3. Click the right mouse button on the device icon that represents the Rosemount 2410:
4. Choose the Write Protect option to open the Rosemount 2410 Tank Hub Write Protect window:
5. Choose Protected in the New State drop-down list.
6. Click the Apply button to save the new state, or click the OK button to save the write protect state and
close the Write Protect window.