Europe - Emerson Rosemount 2410 Reference Manual

Tank hub
Hide thumbs Also See for Rosemount 2410:
Table of Contents

Advertisement

Product Certifications
March 2017
B.5 Europe
E1
ATEX Flame-proof
Certificate: FM10ATEX0012X
Standards: EN 60079-0:2009,
EN 60079-1:2007,
EN 60079-7:2007,
EN 60079-11:2007,
EN 60079-26:2007,
EN 60079-27:2008,
EN 60529:1992 + A1:2000
Ex marking
Comm. Bus
Ex d e [ib] IIB T4
FISCO
HART/ 4-20mA
Ex d e [ia IIC] IIB T4
Active
HART/ 4-20mA
Ex d e ib IIB T4
Passive
Ex d e [ib] IIB T4
Fieldbus
Special Conditions for Safe Use (X):
1. The flamepaths of the equipment are not intended to be
repaired. Consult the manufacturer if repair of the flamepath
joints is necessary.
122
Ui
Ii
Pi
Ci
μ
V
mA
W
F
-
-
-
-
-
-
-
-
30
300
1
0
-
-
-
-
Markings:
II 2(2) G Ex d e [ib] IIB T4
Ta = -50°C to 70°C; IP66, IP67
II 2(1) G Ex d e [ia IIC] IIB T4
Ta = -50°C to 70°C; IP66, IP67
II 2 G Ex d e ib IIB T4
Ta = -50°C to 70°C; IP66, IP67
Li
Uo
Io
Po
mH
V
mA
W
-
15
354
5.32
-
23.1
95.3
0.55
0
-
-
-
-
15
200
3
Reference Manual
00809-0100-2410, Rev DA
Co
Lo
Group
μ
F
mH
-
-
IIB
0.14
3.9
IIC
1.0
15
IIB
3.67
33
IIA
-
-
IIB
1.99
143
IIB
Product Certifications