Emerson Rosemount 2410 Reference Manual page 26

Tank hub
Hide thumbs Also See for Rosemount 2410:
Table of Contents

Advertisement

Overview
March 2017
TankMaster HMI software
Rosemount TankMaster is a powerful Windows-based Human Machine Interface (HMI) for complete tank
inventory management. It provides configuration, service, set-up, inventory, and custody transfer
functions for Rosemount Tank Gauging systems and other supported instruments.
TankMaster is designed to be used in the Microsoft
measurement data from your Local Area Network (LAN).
The TankMaster WinOpi program lets the operator monitor measured tank data. It includes alarm
handling, batch reports, automatic report handling, historical data sampling as well as inventory
calculations such as Volume, Observed Density and other parameters. A plant host computer can be
connected for further processing of data.
The TankMaster WinSetup program is a graphical user interface for installation, configuration and service
of devices in the Rosemount Tank Gauging system.
Rosemount 2460 System Hub
The Rosemount 2460 System Hub is a data concentrator that continuously polls and stores data from
field devices such as radar level gauges and temperature transmitters in a buffer memory. Whenever a
request for data is received, the system hub can immediately send data from the updated buffer memory
for a group of tanks.
Rosemount 2410 Tank Hub
The Rosemount 2410 Tank Hub acts as a power supply to the connected field devices in the hazardous
area using the intrinsically safe Tankbus.
The tank hub collects measurement data and status information from field devices on a tank. It has two
external buses for communication with various host systems.
There are two versions of the Rosemount 2410 Tank Hub; one for single tank operation and one for
multiple tanks operation. The multiple tanks version of the Rosemount 2410 supports up to 10 tanks
and 16 devices. With the Rosemount 5300 and Rosemount 5400 level transmitters the Rosemount 2410
supports up to 5 tanks.
The Rosemount 2410 is equipped with two relays which support configuration of up to 10 "virtual" relay
functions allowing you to specify several source signals for each relay.
The Rosemount 2410 supports Intrinsically Safe (IS) and Non-Intrinsically Safe (Non-IS) analog 4-20 mA
inputs/outputs. By connecting an Emerson
output, the tank hub is capable of wireless communication with an Emerson Wireless Gateway in a
WirelessHART
16
®
network.
®
Windows environment providing easy access to
Wireless 775 THUM
Adapter to the IS HART 4-20 mA
Reference Manual
00809-0100-2410, Rev DA
Overview

Hide quick links:

Advertisement