Emerson Rosemount 2410 Reference Manual page 100

Tank hub
Hide thumbs Also See for Rosemount 2410:
Table of Contents

Advertisement

Service and Troubleshooting
March 2017
6. Click the Start button to start simulating the tank parameters.
7. In the WinSetup workspace the Rosemount 2410 icon changes to the following appearance to
indicate that Simulation Mode is active:
Note
Simulation continues for the specified period of time. It can also be stopped manually at any time by
pressing the Stop button in the Simulation window.
Advanced Simulation
If a Calculate Parameter check-box is selected, the simulation parameter is calculated based on input data
from the holding registers Simulation HREGS 3800 to 4056. You can simulate one or more parameters
simultaneously.
Figure 6-3. Calculation parameter
Product temperature
For Average Temperature, the temperature element positions must be configured:
a. Right-click the auxiliary tank device (ATD) icon in the WinSetup workspace.
b. Choose the Properties option.
c. Select the Average Temperature Calculation tab.
d. The resulting product average temperature is available in input register IR2100 (tank 1). It is also
Volume
The Volume Calculation function must be activated in order to enable advanced Volume simulation.
See
"Volume configuration" on page 148
The volume calculation result is presented in input register IR4702, IR3400 (tank 1) and in input register
area starting with IR30000 (IR30148 for tank 1).
Observed density
To simulate Observed Density the Hybrid Density function must be activated. See
calculation" on page 144
The resulting Observed Density is available in input register IR3500 (tank 1). It is also available in input
register area starting with IR30000 (IR30116 for tank 1).
90
See the Rosemount Tank Gauging System Configuration Manual (Document No. 00809-0300-5100)
for more information.
available in input register area starting with IR30000 (IR30044 for tank 1).
for more information.
Simulation mode active
for more information.
Reference Manual
00809-0100-2410, Rev DA
"Hybrid density
Service and Troubleshooting

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents