Emerson Rosemount 2410 Reference Manual page 64

Tank hub
Hide thumbs Also See for Rosemount 2410:
Table of Contents

Advertisement

Installation
March 2017
Optional secondary bus
In addition to the Tankbus an optional intrinsically safe bus is available for communication with devices
not compatible with F
mA analog input/output communication.
IS terminal block for SIL safety systems
For Safety Integrity Level (SIL) systems the Rosemount 2410 has a terminal block with a SIL Alarm output
for connection to a Rosemount 5900S Radar Level Gauge.
Figure 3-21. IS/Exi terminal block for SIL systems
Table 3-12. Terminal assignment for SIL version of the Rosemount 2410 IS terminal block
Terminal
1a
1b
2a
2b
3
4
5
6
GND_1
GND_2
54
fieldbus. It allows you to connect devices for intrinsically safe HART 4-20
OUNDATION
IS/Exi
Designation
Function
FB +
Intrinsically Safe Tankbus positive (+) terminal
FB +
Intrinsically Safe Tankbus positive (+) terminal
FB -
Intrinsically Safe Tankbus negative (-) terminal
FB -
Intrinsically Safe Tankbus negative (-) terminal
IS I/O+
IS Input/Output +
IS I/O -
IS Input/Output -
SIL Alarm input -
Alarm -
(connect to terminal block on Rosemount 5900S)
SIL Alarm input+
Alarm +
(connect to terminal block on Rosemount 5900S)
GND_1
Housing chassis/Tankbus shield
GND_2
Housing chassis/Tankbus shield
SIL Alarm
Ground screws