4.2.1.1.1
AC Operation – Replace the Fuses
DISCONNECT THE POWER SUPPLY BEFORE PROCEEDING!
FOR CONTINUED OPERATOR SAFETY, ALWAYS REPLACE THE FUSES
WITH THE CORRECT TYPE AND RATING.
Do these steps to replace the AC fuses (Figure 4-6):
1. Unseat the fuse holder from the IEC power module.
a. Use the slot to pry the holder outward from the IEC power module.
b. Pull the holder straight out, and then swing the holder away from the module.
2. Remove and replace the fuses as needed. Use T1.00A 5mm fuses for 115V and 230V
AC operation.
3. Re-seat the fuse holder in the IEC power module.
Rear Panel Connectors
Figure 4-6. AC Fuse Replacement
4–13
SLM-5650A Satellite Modem
Revision 10