7.2.3.10 (CONFIG:) Remote
Remote Control:
SerialConfig
Use the arrow keys to select Mode, SerialConfig, or EthernetConfig. Press [ENT].
(CONFIG:) Remote Mode
Use the arrow keys to select Local, Serial, or Serial+Ethernet. Press [ENT].
Local mode limits your access to remote operations. You may only
monitor the status of the modem.
(CONFIG:) Remote SerialConfig
Remote Control:
For serial communications, use the arrow keys to select Interface, Format, or Baudrate.
Press [ENT].
(CONFIG:) Remote SerialConfig Interface
M&C Bus Interface:
RS485-4W
Use the arrow keys to select RS232, RS485-2W (2-wire), RS485-4W (4-wire), TTL
(Switch), or CRS-500. Press [ENT].
With RS-232 Selected:
Local M&C Bus Address:
With RS-485 Selected:
Local M&C Bus Address:
Front Panel Operation
Mode:Serial
EthernetConfig
Interface
Format
Baudrate
RS232
TTL(Switch) CRS-500
When you select RS-232, the local M&C Bus Address displays 0000.
Addressing is not supported by RS-232 or TTL (Switch) because they
are not multi-drop communication standards.
If you select RS-485, the display will show address 0001 to 9999. This
address can be changed using the front panel. The most significant
digit is for Comtech EF Data redundancy switches.
If you select TTL (Switch), this enables interoperation with the CRS-311
(1:1) or CRS-300 (1:N) redundancy switches.
0000
0001
7–30
(E)
(E)
RS485-2W
(E)
SLM-5650A Satellite Modem
Revision 10
MN-SLM-5650A