Scan Transmit Partial Sequence to transmit partial sequences. (Any fields in the
sequence where no data match occurred will be skipped in the output.) If you have
programmed a
sequence is transmitted. Default = Discard Partial Sequence.
Transmit Partial Sequence
Require Output Sequence
When an output sequence is Required, all output data must conform to an edited
sequence or the scanner will not transmit the output data to the host device. When
it's On/Not Required, the scanner will attempt to get the output data to conform to
an edited sequence but, if it cannot, the scanner transmits all output data to the
host device as is.
When the output sequence is Off, the bar code data is output to the host as the
scanner decodes it. Default = Off.
No Read
With No Read turned On, the scanner notifies you if a code cannot be read. If using
an EZConfig-Scanning Tool Scan Data Window (see page 148), an "NR" appears
when a code cannot be read. If No Read is turned Off, the "NR" will not appear.
Default = Off.
Voyager 1250g User Guide
Sequence Timeout
Required
*Off
On
(page 58) and the timeout is reached, the partial
* Discard Partial Sequence
On/Not Required
59