Telepen Output

Using AIM Telepen Output, the scanner reads symbols with start/stop pattern 1
and decodes them as standard full ASCII (start/stop pattern 1). When Original
Telepen Output is selected, the scanner reads symbols with start/stop pattern 1
and decodes them as compressed numeric with optional full ASCII (start/stop pat-
tern 2). Default = AIM Telepen Output.

Telepen Redundancy

If you are encountering errors when reading Telepen bar codes, you may want to
adjust the redundancy count. Redundancy adjusts the number of times a bar code
is decoded before transmission, which may reduce the number of errors. Note that
the higher the redundancy count, the longer it will take to decode the bar code. To
adjust the redundancy, scan the Telepen Redundancy bar code below, then scan a
redundancy count between 0 and 10 on the
Then scan the

Telepen Message Length

Scan the bar codes below to change the message length. Refer to
Description
= 1-80. Minimum Default = 3, Maximum Default = 80.
Minimum Message Length
114
* AIM Telepen Output
Save
bar code. Default = 0.
(page 88) for additional information. Minimum and Maximum lengths
Programming Chart
Telepen Redundancy
Original Telepen Output
on page 202.
Message Length
Maximum Message Length