When Check Digit is set to Validate and Transmit, the scanner only reads Inter-
leaved 2 of 5 bar codes printed with a check digit, and will transmit this digit at the
end of the scanned data. Default = No Check Digit.

Interleaved 2 of 5 Redundancy

If you are encountering errors when reading Interleaved 2 of 5 bar codes, you may
want to adjust the redundancy count. Redundancy adjusts the number of times a
bar code is decoded before transmission, which may reduce the number of errors.
Note that the higher the redundancy count, the longer it will take to decode the bar
code. To adjust the redundancy, scan the Interleaved 2 of 5 Redundancy bar code
below, then scan a redundancy count between 0 and 10 on the
on page 202. Then scan the

Interleaved 2 of 5 Message Length

Scan the bar codes below to change the message length. Refer to
Description
lengths = 2-80. Minimum Default = 6, Maximum Default = 80.
Minimum Message Length
96
* No Check Digit
Validate and Transmit
(page 88) for additional information. Minimum and Maximum
Save
bar code. Default = 0.