Rs232 Timeout - Honeywell Voyager 1250g User Manual

Single-line laser scanner
Hide thumbs Also See for Voyager 1250g:
Table of Contents

Advertisement

Flow Control with Timeout: The scanner asserts RTS when it has data to send and
waits for a delay (see
host. If the delay time expires and CTS is not asserted, the device transmit buffer is
cleared and scanning may resume.
Character-Based Flow Control with Timeout: The scanner asserts RTS when it
has a character to send and waits for a delay (see
CTS to be asserted by the host. If the delay time expires and CTS is not asserted,
the device transmit buffer is cleared and scanning may resume.
Default = RTS/CTS Off.
Two-Direction Flow Control

RS232 Timeout

When using Flow Control with Timeout, you must program the length of the delay
you want to wait for CTS from the host. Set the length (in milliseconds) for a time-
out by scanning the bar code below, then setting the timeout (from 1-5100 milli-
seconds) by scanning digits from the
scanning Save. Default = 1000 ms (1 second).
Voyager 1250g User Guide
RS232 Timeout
Flow Control, No Timeout
Character-Based Flow
Control with Timeout
on page 33) for CTS to be asserted by the
RS232 Timeout
Programming Chart
RS232 Timeout
on page 33) for
Character-Based Flow Control,
No Timeout
Flow Control with Timeout
* RTS/CTS Off
on page 202, then
33