Require Output Sequence; Multiple Symbols - Honeywell Xenon 1900 User Manual

Area-imaging scanners
Hide thumbs Also See for Xenon 1900:
Table of Contents

Advertisement

Scan Discard Partial Sequence to discard partial sequences when the output
sequence operation is terminated before completion. Scan Transmit Partial
Sequence to transmit partial sequences. (Any fields in the sequence where no data
match occurred are skipped in the output.)
Transmit Partial Sequence

Require Output Sequence

When an output sequence is Required, all output data must conform to an edited
sequence or the scanner will not transmit the output data to the host device. When
it's On/Not Required, the scanner will attempt to get the output data to conform to
an edited sequence but, if it cannot, the scanner transmits all output data to the
host device as is.
When the output sequence is Off, the bar code data is output to the host as the
scanner decodes it. Default = Off.
Note: This selection is unavailable when the Multiple Symbols Selection is turned on.

Multiple Symbols

When this programming selection is turned On, it allows you to read multiple sym-
bols with a single pull of the scanner's trigger. If you press and hold the trigger,
aiming the scanner at a series of symbols, it reads unique symbols once, beeping
(if turned on) for each read. If using a Granit scanner, the scanner also vibrates. The
Xenon/Granit User Guide
Required
*Off
* Discard Partial Sequence
On/Not Required
139