length (in milliseconds) for this timeout by scanning the bar code below, then set-
ting the timeout (from 0-65535 milliseconds) by scanning digits from the
Programming
Note: The Addenda Timeout setting is applied to all addenda and coupon code searches.
EAN/JAN-13 Addenda Separator
When this feature is On, there is a space between the data from the bar code and
the data from the addenda. When turned Off, there is no space.
Default = Off.
Note: If you want to enable or disable EAN13 with Extended Coupon Code, refer to
EAN-13 with Extended Coupon Code

EAN/JAN-13 Redundancy

If you are encountering errors when reading EAN/JAN-13 bar codes, you may want
to adjust the redundancy count. Redundancy adjusts the number of times a bar
code is decoded before transmission, which may reduce the number of errors. Note
that the higher the redundancy count, the longer it will take to decode the bar code.
To adjust the redundancy, scan the EAN/JAN-13 Redundancy bar code below, then
scan a redundancy count between 0 and 10 on the
202. Then scan the
Voyager 1250g User Guide
Chart, then scanning Save. Default = 100.
* On
Save
bar code. Default = 0.
Addenda Timeout
(page 118).
EAN/JAN-13 Redundancy
Off
Programming Chart
UPC-A/
on page
131