UPC-E0 Addenda Required

When Required is scanned, the scanner will only read UPC-E bar codes that have
addenda. Default = Not Required.

Addenda Timeout

You can set a time during which the scanner looks for an addenda. If an addenda is
not found within this time period, the data can be either transmitted or discarded,
based on the setting you are using for
the length (in milliseconds) for this timeout by scanning the bar code below, then
setting the timeout (from 0-65535 milliseconds) by scanning digits from the
Programming
Note: The Addenda Timeout setting is applied to all addenda and coupon code searches.
UPC-E0 Addenda Separator
When this feature is On, there is a space between the data from the bar code and
the data from the addenda. When turned Off, there is no space. Default = On.

UPC-E0 Redundancy

If you are encountering errors when reading UPC-E0 bar codes, you may want to
adjust the redundancy count. Redundancy adjusts the number of times a bar code
is decoded before transmission, which may reduce the number of errors. Note that
the higher the redundancy count, the longer it will take to decode the bar code. To
Voyager 1250g User Guide
Required
Chart, then scanning Save. Default = 100.
* On
UPC-E0 Addenda Required
Addenda Timeout
* Not Required
(page 123). Set
Off