Freqrol Inverter Parameter List - Mitsubishi Electric FX3U-232-BD User Manual

Melsec-f fx series programmable controllers data communication edition
Table of Contents

Advertisement

FX Series PLC User's Manual - Data Communication Edition
Inverter Communication
12.5

FREQROL Inverter Parameter List

This section shows the list of parameters provided in FREQROL F800, A800, F700, A700, E700, V500, F500,
A500, E500 and S500 Series inverters.
For details on each function, refer to the respective inverter manual.
12.5.1 Parameters in V500, F500, A500, E500, and S500 Series
The following parameters are provided in FREQROL inverters. (For details, make sure to refer to the
respective inverter manual.)
FREQROL V500 Series FREQROL F500 Series FREQROL A500 Series FREQROL E500 Series FREQROL S500 Series
Pr
Function
Name
No.
Torque boost
0
(manual)
Maximum speed
1
(simple mode)
Minimum speed
2
(simple mode)
3
Base frequency
Multi-speed
setting
4
(high speed)
(simple mode)
Multi-speed
Basic
setting
functions
5
(middle speed)
(simple mode)
Multi-speed
setting
6
(low speed)
(simple mode)
Acceleration time
7
(simple mode)
Deceleration time
8
(simple mode)
Electronic thermal
9
O/L relay
DC injection brake
10
operation speed
DC injection brake
11
operation time
DC injection brake
Standard
12
voltage
operation
13
Starting speed
functions
15
Jog speed setting
Jog acceleration/
16
deceleration time
Standard
MRS input
17
operation
selection
function
(V500
Series
operation
Base frequency
selection
19
voltage
functions)
Pr
Pr
Name
No.
No.
0
Torque boost
0
Torque boost
Maximum
Maximum
1
1
frequency
frequency
Minimum
Minimum
2
2
frequency
frequency
3
Base frequency
3
Base frequency
Multi-speed
Multi-speed
4
setting
4
setting
(high speed)
(high speed)
Multi-speed
Multi-speed
5
setting
5
setting
(middle speed)
(middle speed)
Multi-speed
Multi-speed
6
setting
6
setting
(low speed)
(low speed)
7
Acceleration time
7
Acceleration time
8
Deceleration time
8
Deceleration time
Electronic thermal
Electronic thermal
9
9
O/L relay
O/L relay
DC injection brake
DC injection brake
10
operation
10
operation
frequency
frequency
DC injection brake
DC injection brake
11
11
operation time
operation time
DC injection brake
DC injection brake
12
12
voltage
voltage
13
Starting frequency
13
Starting frequency
Load pattern
Load pattern
14
14
selection
selection
15
Jog frequency
15
Jog frequency
Jog acceleration/
Jog acceleration/
16
16
deceleration time
deceleration time
MRS input
MRS input
17
17
selection
selection
High speed
18
maximum
frequency
Base frequency
Base frequency
19
19
voltage
voltage
Pr
Name
Name
No.
*3
0
Torque boost
Maximum
1
frequency
Minimum
2
frequency
3
Base frequency
Multi-speed
4
setting
(high speed)
Multi-speed
5
setting
(middle speed)
Multi-speed
6
setting
(low speed)
7
Acceleration time
8
Deceleration time
Electronic thermal
9
O/L relay
DC injection brake
10
operation
frequency
DC injection brake
11
operation time
DC injection brake
12
voltage
13
Starting frequency
Load pattern
14
*3
*3
selection
15
Jog frequency
Jog acceleration/
16
deceleration time
High speed
18
maximum
frequency
Base frequency
19
*3
*3
voltage
12 Related Data
12.5 FREQROL Inverter Parameter List
Pr
Name
No.
*3
*3
0
Torque boost
Maximum
1
frequency
Minimum
2
frequency
*3
*3
3
Base frequency
Multi-speed
4
setting
(high speed)
Multi-speed
5
setting
(middle speed)
Multi-speed
6
setting
(low speed)
7
Acceleration time
8
Deceleration time
Electronic thermal
9
O/L relay
DC injection brake
10
operation
frequency
DC injection brake
11
operation time
DC injection brake
12
voltage
13
Starting frequency
Load pattern
14
*3
selection
15
Jog frequency
Jog acceleration/
16
deceleration time
RUN key rotation
17
direction selection
Base frequency
19
*3
voltage
E-151
A
B
C
D
E
F
G
H