Mitsubishi Electric FX3U-232-BD User Manual page 519

Melsec-f fx series programmable controllers data communication edition
Table of Contents

Advertisement

FX Series PLC User's Manual - Data Communication Edition
Inverter Communication
FREQROL F700 Series
Pr
Function
No.
PID control automatic
127
switchover frequency
128 PID action selection
129 PID proportional band
130 PID integral time
PID operation
131 PID maximum
132 PID minimum
133 PID action set point
134 PID differential time
Commercial power-
supply switchover
135
sequence output
terminal selection
MC switchover interlock
136
time
Commercial
137 Waiting time at a start
power
Commercial power-
supply-inverter
supply operation
switch-over
138
switchover selection at
an alarm
Automatic switchover
frequency between
139
inverter and commercial
power-supply operation
Backlash acceleration
140
stopping frequency
Backlash acceleration
141
stopping time
Backlash
measures
Backlash deceleration
142
stopping frequency
Backlash deceleration
143
stopping time
Speed setting
144
switchover
PU display language
PU
145
selection
Stall prevention level at
148
0V input.
Stall prevention level at
149
10V input.
Output current detection
150
level
Current
detection
Output current detection
151
signal delay time
Zero current detection
152
level
Zero current detection
153
time
Voltage reduction
154
selection during stall
prevention operation
RT signal reflection time
155
selection
Stall prevention
156
operation selection
FREQROL A700 Series
Pr
Name
Name
No.
PID control automatic
127
switchover frequency
128 PID action selection
129 PID proportional band
130 PID integral time
131 PID upper limit
132 PID lower limit
133 PID action set point
134 PID differential time
Electronic bypass
135
sequence selection
MC switchover interlock
136
time
137 Start waiting time
Bypass selection at an
138
alarm
Automatic switchover
139
frequency from inverter
to bypass operation
Backlash acceleration
140
stopping frequency
Backlash acceleration
141
stopping time
Backlash deceleration
142
stopping frequency
Backlash deceleration
143
stopping time
Speed setting
144
switchover
PU display language
145
selection
Stall prevention level at
148
0V input
Stall prevention level at
149
10V input
Output current detection
150
level
Output current detection
151
signal delay time
Zero current detection
152
level
Zero current detection
153
time
Voltage reduction
154
selection during stall
prevention operation
RT signal function
155
validity condition
selection
Stall prevention
156
operation selection
FREQROL E700 Series
Pr
Name
No.
PID control automatic
127
switchover frequency
128 PID action selection
129 PID proportional band
130 PID integral time
131 PID upper limit
132 PID lower limit
133 PID action set point
134 PID differential time
PU display language
145
selection
Built-in potentiometer
146
switching
Output current detection
150
level
Output current detection
151
signal delay time
Zero current detection
152
level
Zero current detection
153
time
Stall prevention
156
operation selection
12 Related Data
12.5 FREQROL Inverter Parameter List
FREQROL D700 Series
Pr
Name
No.
PID control automatic
127
switchover frequency
128 PID action selection
129 PID proportional band
130 PID integral time
131 PID upper limit
132 PID lower limit
133 PID action set point
134 PID differential time
PU display language
145
selection
Built-in potentiometer
146
switching
Output current detection
150
level
Output current detection
151
signal delay time
Zero current detection
152
level
Zero current detection
153
time
Stall prevention
156
operation selection
E-177
A
B
C
D
E
F
G
H
I
Apx.A