Inverter Communication
Read devices: D100 = Motor rotation direction, D101 = Frequency, D102 = Time
X001
Read
command
M0
Drive
contact
Inverter station
M8029
Execution
complete flag
S
S
1
2
FNC272
K6
K2201
IVRD
number:
Inverter parameter number (decimal)
0 to 31
FNC272
K6
K201
IVRD
FNC272
K6
K1201
IVRD
9 Creating Programs (FX3S, FX3G, FX3GC, FX3U, FX3UC)
9.6 Inverter Parameter Reading (PLC  Inverter) [FNC272 / IVRD]
SET
M0
D 
n
Motor rotation directionD100
D100
K1
Communication channel K1:ch1
Read value storage destination
FrequencyD101
D101
K1
TimeD102
D102
K1
The unit is specified by Pr. 200.