Setting For Using Got Transparent Function - Mitsubishi Electric FX3U-232-BD User Manual

Melsec-f fx series programmable controllers data communication edition
Table of Contents

Advertisement

FX Series PLC User's Manual - Data Communication Edition
Programming Communication
6.1.2

Setting for using GOT transparent function

Arrange the setting in accordance with the connection status of the used equipment. This subsection explains
the setting when the GOT and PLC are directly connected (by serial connection).
For the GX Developer operation procedures, refer to the GX Developer Operating Manual.
[Transparent function of the GOT1000 Series]
The following setting is required when connecting the FX
transparent function of the GOT1000 Series.
If the following setting is not provided, a communication error will occur.
1
Displaying the "PLC side I/F Detailed Setting of GOT" window
Double-click GOT
2
Setting the CPU unit
Set "PLC Mode" to "FXCPU", and select "via GOT(direct coupled) transparent mode".
[Transparent function of the GOT-F900 Series]
The following setting is required when connecting the FX
transparent function of the GOT-F900 Series.
1
Displaying the "PLC side I/F Detailed Setting of GOT" window
Double-click GOT
2
Setting the CPU unit
Set "PLC Mode" to "FXCPU", and select "via GOT(direct coupled) transparent mode".
Check "via GOT-F900 transparent mode". However, it cannot be checked if "USB" is selected on the "PC side
I/F Serial Setting" window.
H-44
on the Transfer Setup dialog box to display the window shown below.
on the Transfer Setup dialog box to display the window shown below.
6 Connection Setting for Personal Computer
6.1 Connection Setting (GX Works2)
/FX
/FX
/FX
/FX
3S
3G
3GC
3U
/FX
/FX
/FX
/FX
3S
3G
3GC
3U
PLC using the
3UC
PLC using the
3UC