FX Series PLC User's Manual - Data Communication Edition
Inverter Communication
FREQROL V500 Series FREQROL F500 Series FREQROL A500 Series FREQROL E500 Series FREQROL S500 Series
Pr
Function
Name
No.
Additional
functions
The parameters Pr. 77 and Pr. 79 cannot be written in computer link operation using the FR-A5NR.
*1.
Can be read or written when the parameter Pr. 77 is set to "801".
*2.
Can be read or written when the parameter Pr. 29 is set to "3".
*3.
Indicates a parameter whose setting is ignored when the advanced magnetic flux vector control mode
is selected.
*4.
Can be set when the parameters Pr. 80 and Pr. 81 are not set to "9999" and the parameter Pr. 60 is
set to "7" or "8".
*5.
Can be read or written when the parameters Pr. 80 and Pr. 81 are not set to "9999" and the parameter
Pr. 77 is set to "801".
*6.
Can be set only in the 200 V/100 V class.
*7.
Cannot be used in inverter communication.
*8.
This inverter communication function cannot read or write Pr. 37.
Set Pr. 37 to "0" when setting or monitoring the frequency in the PLC.
If any value other than "0" is set to Pr. 37 and the instruction code HFF is set to "01", the frequency
may not be set or monitored normally (in the 400 V class of the E500 series and S500 series).
(In the 200 V and 100 V classes of the E500 series, the frequency may not be set or monitored
normally if any value other than "0" is set to Pr. 37 without regard to the setting of the instruction code
HFF.)
E-172
Pr
Pr
Name
No.
No.
Pr
Name
Name
No.
12 Related Data
12.5 FREQROL Inverter Parameter List
Pr
Name
No.
PU disconnection
n17
detection/PU
(993)
setting lock