FX Series PLC User's Manual - Data Communication Edition
Inverter Communication
Pr
Function
No.
Group
243
T041
244
H100
245
G203
Slip
246
G204
compensation
247
G205
248
A006
249
H101
250
G106
251
H200
Frequency
252
T050
compensation
253
T051
function
254
A007
255
E700
256
E701
Life check
257
E702
258
E703
259
E704
260
E602
261
A730
262
A731
263
A732
Power failure
stop
264
A733
265
A734
266
A735
267
T001
268
M022
Load torque
high speed
frequency
control
Stop-on contact
control
FREQROL F800 Series
Pr
Name
Terminal 1 added compensation
amount (terminal 4)
Cooling fan operation selection
Rated slip
Slip compensation time constant
Constant-power range slip
compensation selection
Self power management selection
Earth (ground) fault detection at start
Stop selection
Output phase loss protection selection
Override bias
Override gain
Main circuit power OFF waiting time
Life alarm status display
Inrush current limit circuit life display
Control circuit capacitor life display
Main circuit capacitor life display
Main circuit capacitor life measuring
PWM frequency automatic switchover
Power failure stop selection
Subtracted frequency at
deceleration start
Subtraction starting frequency
Power-failure deceleration time 1
Power-failure deceleration time 2
Power failure deceleration time
switchover frequency
Terminal 4 input selection
Monitor decimal digits selection
12.5 FREQROL Inverter Parameter List
FREQROL A800 Series
Pr
Pr
No.
Group
Terminal 1 added compensation
243
T041
amount (terminal 4)
244
H100
Cooling fan operation selection
245
G203
Rated slip
246
G204
Slip compensation time constant
Constant-power range slip
247
G205
compensation selection
248
A006
Self power management selection
249
H101
Earth (ground) fault detection at start
250
G106
Stop selection
251
H200
Output phase loss protection selection
252
T050
Override bias
253
T051
Override gain
254
A007
Main circuit power OFF waiting time
255
E700
Life alarm status display
256
E701
Inrush current limit circuit life display
257
E702
Control circuit capacitor life display
258
E703
Main circuit capacitor life display
259
E704
Main circuit capacitor life measuring
260
E602
PWM frequency automatic switchover
261
A730
Power failure stop selection
Subtracted frequency at
262
A731
deceleration start
263
A732
Subtraction starting frequency
264
A733
Power-failure deceleration time 1
265
A734
Power-failure deceleration time 2
Power failure deceleration time
266
A735
switchover frequency
267
T001
Terminal 4 input selection
268
M022
Monitor decimal digits selection
Stop-on contact/load torque high-
270
A200
speed frequency control selection
271
A201
High-speed setting maximum current
272
A202
Middle-speed setting minimum current
273
A203
Current averaging range
274
A204
Current averaging filter time constant
Stop-on contact excitation current
275
A205
low-speed multiplying factor
PWM carrier frequency at stop-on
276
A206
contact
12 Related Data