7.1
Example of Printing Using RS Instruction (Using RS-232C Connection)
In this example, a printer with an RS-232C interface is connected to a PLC, and data sent from the PLC is
printed.
1. System configuration
Use a communication cable suitable to the pin arrangement of the printer connector.
(For representative wiring, refer to Chapter 4.)
2. Communication format
Align the communication format in the PLC with that in the printer used.
(The table below shows the communication format in the main unit.)
Data length
Parity
Stop bit
Baud rate
Header
Terminator
Control line (hardware)
Communication method (protocol)
Sending
FX
232-BD
2N-
8-bit
Even
2-bit
2400 bps
Not provided
Not provided
Not provided
Non-protocol method