Communication Setting Using Parameter Method (Gx Works2) - Mitsubishi Electric FX3U-232-BD User Manual

Melsec-f fx series programmable controllers data communication edition
Table of Contents

Advertisement

FX Series PLC User's Manual - Data Communication Edition
Parallel Link
5.2

Communication Setting Using Parameter Method (GX Works2)

Communication settings may be changed using the parameter method with GX Works2, GX Developer,
FXGP/WIN for Windows and FX-30P handy programming panel. This section describes how to change
parameters with GX Works2.
For details on GX Developer operating procedure, refer to GX Developer Operating Manual.
5.2.1
Operating procedure
This subsection explains the serial communication setting method.
Suppose that GX Works2 is already started up.
1
Opening the parameter setting window
In the project view area of the navigation window, double-click [Parameter]  [PLC Parameter].
If the navigation window is not displayed, select [View]  [Docking Window]  [Navigation] from
the menu bar.
2
Setting the serial communication (parameters)
Click the [PLC System(2)] tab in the dialog box.
Select a channel to be used, and make sure that the "Operate Communication Setting" box is
cleared.
If a check mark is there, clear it.
Click [End].
3
Writing parameters and program to the PLC
Select [Online]  [Write to PLC] from the menu bar, click [Parameter + Program], and then click
[Execute].
For details on FXGP/WIN operating procedure, refer to section 5.3.
For details on FX-30P operating procedure, refer to FX-30P Operation Manual.
5 Communication Setting (Initialization) in FX Programmable Controller
5.2 Communication Setting Using Parameter Method (GX Works2)
A
B
C
D
E
F
G
H
I
Apx.A
C-33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents