Mitsubishi Electric FX3U-232-BD User Manual page 518

Melsec-f fx series programmable controllers data communication edition
Table of Contents

Advertisement

FX Series PLC User's Manual - Data Communication Edition
Inverter Communication
FREQROL F700 Series
Pr
Function
No.
100 V/F1 (first frequency)
V/F1 (first frequency
101
voltage)
V/F2 (second
102
frequency)
V/F2 (second frequency
103
voltage)
104 V/F3 (third frequency)
Adjustable 5
points V/F
V/F3 (third frequency
105
voltage)
106 V/F4 (fourth frequency) 106 V/F4(fourth frequency)
V/F4 (fourth frequency
107
voltage)
108 V/F5 (fifth frequency)
V/F5 (fifth frequency
109
voltage)
Third
functions
PU communication
117
station
PU communication
118
speed
PU communication stop
119
bit length.
PU communication
120
parity check
PU connector
Number of PU
communication
121
communication retries
PU communication
122
check time interval
PU communication
123
waiting time setting
PU communication CR/
124
LF presence/absence
selection
Terminal 2 frequency
125
setting gain frequency
Terminal 4 frequency
126
setting gain frequency
E-176
FREQROL A700 Series
Pr
Name
No.
100 V/F1(first frequency)
V/F1(first frequency
101
voltage)
102 V/F2(second frequency)
V/F2(second frequency
103
voltage)
104 V/F3(third frequency)
V/F3(third frequency
105
voltage)
V/F4(fourth frequency
107
voltage)
108 V/F5(fifth frequency)
V/F5(fifth frequency
109
voltage)
Third acceleration/
110
deceleration time
111 Third deceleration time
112 Third torque boost
Third V/F (base
113
frequency)
Third stall prevention
114
operation current
Third stall prevention
115
operation frequency
Third output frequency
116
detection
PU communication
117
station number
PU communication
118
speed
PU communication stop
119
bit length
PU communication
120
parity check
Number of PU
121
communication retries
PU communication
122
check time interval
PU communication
123
waiting time setting
PU communication CR/
124
LF presence/absence
selection
Terminal 2 frequency
125
setting gain frequency
Terminal 4 frequency
126
setting gain frequency
FREQROL E700 Series
Pr
Name
No.
PU communication
117
station number
PU communication
118
speed
PU communication stop
119
bit length
PU communication
120
parity check
Number of PU
121
communication retries
PU communication
122
check time interval
PU communication
123
waiting time setting
PU communication
124
CR/LF selection
Terminal 2 frequency
125
setting gain frequency
Terminal 4 frequency
126
setting gain frequency
12.5 FREQROL Inverter Parameter List
FREQROL D700 Series
Pr
Name
No.
PU communication
117
station number
PU communication
118
speed
PU communication stop
119
bit length
PU communication
120
parity check
Number of PU
121
communication retries
PU communication
122
check time interval
PU communication
123
waiting time setting
PU communication
124
CR/LF selection
Terminal 2 frequency
125
setting gain frequency
Terminal 4 frequency
126
setting gain frequency
12 Related Data