When Combined With Computer Link Communication - Mitsubishi Electric FX3U-232-BD User Manual

Melsec-f fx series programmable controllers data communication edition
Table of Contents

Advertisement

FX Series PLC User's Manual - Data Communication Edition
Non-Protocol Communication (RS/RS2 Instruction)
10.3

When Combined with Computer Link Communication

In FX
, FX
, FX
3S
3G
RS-485) using the RS instruction can be changed over to a protocol dedicated to computer link by the
following methods.
The protocol supported by the communication port can be checked in the operation mode display device
(D8149).
1. When changing over using RUN mode and STOP mode
Set the communication format as shown below to use non-protocol communication (in accordance with RS-
232C or RS-485) using the RS instruction while in RUN mode and then use computer link while in STOP
mode.
Set computer link using parameters.
Make sure to set the communication format used in the RS instruction to D8120, and write it before executing
the RS instruction.
X0
MOV
RS D1
2. When changing over using the RS instruction while in RUN mode
When changing over non-protocol communication using the RS instruction to computer link while in RUN
mode, set the RS instruction to OFF, and then overwrite the communication format (D8120) to "H0000".
Set computer link using parameters.
Before starting up the RS instruction again, make sure to properly overwrite the communication format
(D8120) used in the RS instruction.
X0
MOV
RS D1
X0
MOV
, FX
and FX
PLCs, non-protocol communication (in accordance with RS-232C or
3GC
3U
3UC
H0086 D8120
P
K1
D2
K1
P
H0086 D8120
K1
D2
K1
H0000 D8120
P
10 When Combined with Another Communication
10.3 When Combined with Computer Link Communication
A
B
C
D
E
F
G
H
I
Apx.A
F-81