Related Data - Mitsubishi Electric FX3U-232-BD User Manual

Melsec-f fx series programmable controllers data communication edition
Table of Contents

Advertisement

FX Series PLC User's Manual - Data Communication Edition
N:N Network

10. Related Data

10.1
Related Device List
10.1.1 For FX
, FX
1N
1NC
1. Bit devices
Device
number
Devices for communication setting
M8038
Parameter setting
M8179
Channel setting
Devices for checking communication status
Serial communication
M8063
error 1 (ch 1)
Serial communication
M8438
error 2 (ch 2)
Data transfer
M8183
sequence error
M8184
Data transfer
to M8190
sequence error
Data transfer
M8191
sequence ON
R
: Read only (used as a contact in program)
R/W : Read or Write
M
: Master station (station No. 0)
L
: Slave station (station No. 1 to 7)
B-54
, FX
, FX
, FX
, FX
2N
2NC
3S
Name
Communication parameter setting flag
Sets the communication port channel to be used
(in the FX
3G
Turns ON when abnormality occurs in serial
communication using ch 1.
Turns ON when abnormality occurs in serial
communication using ch 2 (in the FX
FX
and FX
3U
Turns ON when a data transfer sequence error
occurs in the master station.
Turns ON when a data transfer sequence error
occurs in a slave station.
However, data transfer sequence errors within
the slave station itself cannot be detected.
Remains ON while data transfer is being
executed.
, FX
, FX
and FX
3G
3GC
3U
Description
, FX
, FX
and FX
).
3GC
3U
3UC
, FX
3G
).
3UC
10 Related Data
10.1 Related Device List
PLCs
3UC
Initial
Detec-
R/W
value
tion
M, L
R
M, L
R/W
M, L
R
,
M, L
R
3GC
L
R
M, L
R
M, L
R

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents