E700 And D700 Series - Mitsubishi Electric FX3U-232-BD User Manual

Melsec-f fx series programmable controllers data communication edition
Table of Contents

Advertisement

FX Series PLC User's Manual - Data Communication Edition
Inverter Communication

9.10.8 E700 and D700 Series

1. Second parameter specification codes for parameter numbers 125, 126, C2 to C7 and C22 to
C25
Parameter
No.
C2
Terminal 2 frequency setting bias frequency
Terminal 2 frequency setting bias
C3
Terminal 2 analog value
125
Terminal 2 frequency setting gain frequency
Terminal 2 frequency setting gain
C4
Terminal 2 analog value
C5
Terminal 4 frequency setting bias frequency
Terminal 4 frequency setting bias
C6
Terminal 4 analog value
126
Terminal 4 frequency setting gain frequency
Terminal 4 frequency setting gain
C7
Terminal 4 analog value
Frequency setting voltage bias frequency (built-in
C22
potentiometer)
Frequency setting voltage bias
C23
(built-in potentiometer)
Frequency setting voltage gain frequency (built-in
C24
potentiometer)
Frequency
C25
potentiometer)
E-116
Name
setting
voltage
gain
9 Creating Programs (FX3S, FX3G, FX3GC, FX3U, FX3UC)
Second parameter specification code
[(decimal) value to be specified in
IVWR instruction for parameter number]
2902 (Only the IVRD instruction)
2903 (Only the IVRD instruction)
2904 (Only the IVRD instruction)
2905 (Only the IVRD instruction)
(built-in
9.10 Second Parameter Specification Codes
S
in IVRD/
2
902
1902
903
1903
904
1904
905
1905
922
1922
923
1923

Hide quick links:

Advertisement

Table of Contents
loading