Mechanical Installation
November 2017
Recommended tools for installation:
A set of small precision screwdrivers (for the terminal blocks)
13 mm open wrench
4 mm Hex key (preferably with a handle)
Large adjustable wrench
Wire cutter, pointed pliers, insulating tape
Laser measurement device or equivalent
RS-485 to USB converter, including drivers
120 Ω (RS-485) resistor
250 Ω (HART
PC or laptop
DC voltmeter and Ohm meter
Complete the following steps before installing the Rosemount 5708.
Power
Make sure grounding is done properly. Connect one end of the cable shield to the power ground. It is
highly recommended to have the same potential grounding to all the Rosemount 5708.
Prepare a 24 Vdc power supply near the Rosemount 5708 mounting location.
Make sure that you use proper cables for wiring. The Rosemount 5708 is a 4-wire device. The voltage
supply and data output (4-20 mA) are carried along two separate two-wire connection cables.
Communications
For RS-485 communication, use shielded, twisted-pair cables with 120 Ω impedance. Make sure the
cables are approved for RS-485 communications.
Route communication cables in proper conduits. Use a proper cable type.
For 4-20 mA communication, use shielded, twisted-pair, low resistance cables. Make sure the cables
are rated for analog signals.
For daisy chaining, a single 4-wire cable can be used, both for RS-485 and the
24 Vdc power supply.
3.2.5

Site and installation information

The information listed on these pages is necessary for configuration of the device.
Material characteristics
Material name:
Material density:
Max. temperature:
14
®
) resistor
3
lbs/ft
tons/m
°F
°C
3
Angle of repose:
Maximum pressure:
Reference Manual
00809-0100-4570, Rev DA
Bar
PSI
Mechanical Installation