Figure 3-5. Inflowing Material
When choosing the installation location, consider the filling and emptying points and maintain at least
24-in. (600 mm) from the filling point.
Fitting
The fitting area should be prepared to ensure the antennas are positioned perpendicular to the ground,
as shown in
Figure 3-6. Keep the Antennas in Vertical Position to the Ground
Mechanical Installation
Minimum
24-in. (600 mm)
Figure
3-6.
90°
Mechanical Installation
November 2017